18.1.3 CU-E12NKE
Cooling Characteristic
[Condition] Indoor temperature: 27/19°C
Remote condition: High fan speed, Cool 16°C
Comp. Hz: F
c
14.500
15.000
15.500
16.000
16.500
5 7 9 1113151719212325272931333537394143
Outdoor Air Temperature (°C)
Outlet Air
TempeatureC
)
230
3.000
3.200
3.400
3.600
3.800
4.000
4.200
5 7 9 111315 17192123 2527293133353739 4143
Outdoor Air Temperature (°C)
Cooling
Capacity (kW)
2.000
2.500
3.000
3.500
4.000
4.500
5.000
5 7 9 111315 17192123 2527293133353739 4143
Outdoor Air Temperature (°C)
Current
(A)
0.680
0.780
0.880
0.980
1.080
5 7 9 111315171921232527 293133 3537394143
Outdoor Air Temperature (°C)
Gas Side Piping
Pressure (MPa
)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-E7NKEW and is the answer not in the manual?

Panasonic CS-E7NKEW Specifications

General IconGeneral
Indoor unit typeWall-mountable
Indoor units quantity1
Indoor unit dimensions (WxDxH)870 x 214 x 290 mm
TimerYes
Built-in displayNo
Cooling capacity (max)- BTU/h
Air conditioner functionscooling, heating
Cooling capacity in watts (max)2050 W
Heating capacity in watts (max)2800 W
Cooling energy efficiency (EER, W/W)4.36
Heating energy efficiency (COP, W/W)4.41
Outdoor units quantity0
Noise level (low speed)20 dB
Noise level (high speed)37 dB
Noise level (medium speed)24 dB
Power requirementsAC 230 V