EasyManuals Logo

Panasonic CS-E7NKEW User Manual

Panasonic CS-E7NKEW
189 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #152 background imageLoading...
Page #152 background image
152
Piping Length Characteristic
[Condition] Indoor temperature: 20/-°C, 7/6°C
Remote condition: High fan speed, Heat 30°C
Comp. Hz: F
h
5.050
5.100
5.150
5.200
5.250
5.300
5.350
3456789101112131415
Piping Length (m)
Heating
Capacity (kW)
6.400
6.500
6.600
6.700
3456789101112131415
Piping Length (m)
Current
(A)
2.870
2.890
2.910
2.930
2.950
3 4 5 6 7 8 9 10 11 12 13 14 15
Piping Length (m)
Gas Side Piping
Pressure (MPa
)
38.200
38.300
38.400
38.500
38.600
38.700
38.800
3456789101112131415
Piping Length (m)
Outlet Air
Temperature (°C
)
230

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-E7NKEW and is the answer not in the manual?

Panasonic CS-E7NKEW Specifications

General IconGeneral
Indoor unit typeWall-mountable
Indoor units quantity1
Indoor unit dimensions (WxDxH)870 x 214 x 290 mm
TimerYes
Built-in displayNo
Cooling capacity (max)- BTU/h
Air conditioner functionscooling, heating
Cooling capacity in watts (max)2050 W
Heating capacity in watts (max)2800 W
Cooling energy efficiency (EER, W/W)4.36
Heating energy efficiency (COP, W/W)4.41
Outdoor units quantity0
Noise level (low speed)20 dB
Noise level (high speed)37 dB
Noise level (medium speed)24 dB
Power requirementsAC 230 V