EasyManuals Logo

Panasonic CS-E7NKEW User Manual

Panasonic CS-E7NKEW
189 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #166 background imageLoading...
Page #166 background image
166
Cooling Characteristic at Different Piping Length
Piping Length Characteristic
[Condition] Indoor temperature: 27/19°C, 35/-°C
Remote condition: High fan speed, Cool 16°C
Comp. Hz: F
c
4.800
4.900
5.000
5.100
34567891011121314151617181920
Piping Length (m)
Cooling
Capacity (kW)
6.580
6.590
6.600
6.610
6.620
6.630
34567891011121314151617181920
Piping Length (m)
Current
(A)
0.900
0.910
0.920
0.930
0.940
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Piping Length (m)
Gas Side Piping
Pressure (MPa
)
15.200
15.300
15.400
15.500
34567891011121314151617181920
Piping Length (m)
Outlet Air
Temperature (°C
)
230

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-E7NKEW and is the answer not in the manual?

Panasonic CS-E7NKEW Specifications

General IconGeneral
Indoor unit typeWall-mountable
Indoor units quantity1
Indoor unit dimensions (WxDxH)870 x 214 x 290 mm
TimerYes
Built-in displayNo
Cooling capacity (max)- BTU/h
Air conditioner functionscooling, heating
Cooling capacity in watts (max)2050 W
Heating capacity in watts (max)2800 W
Cooling energy efficiency (EER, W/W)4.36
Heating energy efficiency (COP, W/W)4.41
Outdoor units quantity0
Noise level (low speed)20 dB
Noise level (high speed)37 dB
Noise level (medium speed)24 dB
Power requirementsAC 230 V