9.6.7. Pump-down Control
To enable pump down operation, at outdoor PCB, set the DS1and DS2 to OFF position.
Press Test Run button for 1 second.
During Pump Down operation, push the Test Run button again for 1 second to stop the pump down operation.
The pump down operation run for 10 minutes.