7
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)
and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry
Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor
-7/-8°C
5. Specifications are subjected to change without prior notice for further improvement.
Protection Device Electronic Control
Dry Bulb Wet Bulb
Indoor Operation Range
Cooling
Maximum 32 23
Minimum 16 11
Heating
Maximum 30 —
Minimum 16 —
+8/10°C
HEAT
Maximum 10 —
Minimum 8 —
Outdoor Operation Range
Cooling
Maximum 43 26
Minimum -15 —
Heating
Maximum 24 18
Minimum -15 —
+8/10°C
HEAT
Maximum — —
Minimum -15 —
MODEL
INDOOR CS-NE9JKE-1, CS-XE9JKE-6
OUTDOOR CU-NE9JKE-1