8
MODEL
INDOOR CS-NE12JKE-1, CS-XE12JKE-6
OUTDOOR CU-NE12JKE-1
Performance Test Condition EUROVENT
Power Supply
Phase, Hz Single, 50
V 230
Min. Mid. Max.
Cooling
Capacity
kW 0.60 3.50 4.00
BTU/h — — —
Kcal/h 520 3010 3440
Running Current A — 4.3 —
Input Power W 120 910 1.17k
Annual Consumption kWh — 455 —
EER
W/W 5.00 3.85 3.42
Kcal/hW 4.33 3.31 2.94
Power Factor % — 92 —
Indoor Noise (H / L / QLo)
dB-A 42 / 29 / 26
Power Level dB 58 / 45 / 42
Outdoor Noise (H / L)
dB-A 48 / -
Power Level dB 63 / -
Heating
Capacity
kW 0.60 4.80 6.60
BTU/h — — —
Kcal/h 520 4130 5680
Running Current A — 5.8 —
Input Power W 115 1.25k 1.85k
COP
W/W 5.22 3.84 3.57
Kcal/hW 4.52 3.30 3.07
Power Factor % — 94 —
Indoor Noise (H / L / QLo)
dB-A 42 / 33 / 30
Power Level dB 58 / 49 / 46
Outdoor Noise (H / L)
dB-A 50 / -
Power Level dB 65 / -
Low Temp. : Capacity (kW) / I.Power (W) / COP 4.78 / 1.64k / 2.91
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 3.86 / 1.74k / 2.22
Max Current (A) / Max Input Power (W) 8.4 / 1.85k
Starting Current (A) 5.8
Compressor
Type Hermetic Motor
Motor Type Brushless (4-poles)
Output Power W 750
Indoor Fan
Type Cross-flow Fan
Material ASG20K1
Motor Type Transistor (8-poles)
Input Power W 47
Output Power W 40
Speed
QLo
Cool/Fan rpm 760
Heat rpm 950
Lo
Cool/Fan rpm 850
Heat rpm 1010
Me
Cool/Fan rpm 1050
Heat rpm 1150
Hi
Cool/Fan rpm 1260
Heat rpm 1300
SHi
Cool/Fan rpm 1320
Heat rpm 1340