18
8 Wiring Connection Diagram
8.1. CS-PC12MKF CU-PC12MKF
Resistance of Indoor Fan Motor Windings
Note: Resistance at 25°C of ambient temperature.
Resistance of Compressor Windings
Note: Resistance at 20°C of ambient temperature.
Resistance of Outdoor Fan Motor Windings
Note: Resistance at 25°C of ambient temperature.
MODEL CS-PC12MKF
CONNECTION CWA921434
BLUE-YELLOW 351.3 Ω
YELLOW-RED 343.9 Ω
MODEL CU-PC12MKF
CONNECTION 2KS210D5AA06
C - R 2.279 Ω
C - S 3.526 Ω
MODEL CU-PC12MKF
CONNECTION CWA951676
BLUE-YELLOW 198 Ω
YELLOW-RED 293 Ω