43
7. Push up the Evaporator and pull out the Cross Flow Fan
from shaft. By then, Fan Motor can be taken out. (Fig. 9)
REMINDER - To reinstall the Fan Motor, put it back in
place, adjust the position of the Fan Motor’s leadwire
appropriately as shown in the Fig. 7 before installing the
Cross Flow Fan.
Fig. 9
15.3. Remote Control Reset
When the batteries are inserted for the first time or the
batteries are replaced, you may notice the indications at
remote control’s display screen blink continuously and not
functionable. If this condition happens, try to reset the
remote control by pushing the reset terminal with a pointing
device.
You may also do the reset to erase the setting at remote
control and restore back the default setting.