6
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (80.6°F D.B.) and outdoor air temperature of 7°C D.B.
(44.6°F D.B.), 6°C W.B. (42.8°F W.B.)
Note
• Specifications are subject to change without notice for further improvement.
Heat Exchanger
Fin Material Aluminium (Pre coat) Aluminium (Pre coat)
Fin Type Slit Fin Corrugated Fin
Row x Stage x FPI 2 x 15 x 21 2 x 20 x 17
Size (W x H x L) mm (inch) 810 x 315 x 25.4 684.6:719.2 x 508 x 44
Air Filter Type
Material P. P. Honey Comb —
Style One-Touch —
Item Unit
Power Source (Phase, Voltage, Cycle)
øSingle
V 230
Hz 50
Input Power
Cooling W 1.75k
Heating W 1.58k
*Annual consumption W 875
Starting Current A 27
Running Current
Cooling A 7.7
Heating A 6.9
Power Factor
Cooling % 99
Heating % 99
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord
Number of core
3 (1.5mm
2
)
Length m 2
Thermostat —
Protection Device —
ITEM UNIT INDOOR UNIT OUTDOOR UNIT