2.  For Heating mode: 
 
 
Note: The value of A, B, C, D will change according to the indoor temperature. 
11.3.5  Automatic Restart Control 
When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to 
four minutes after power supply resumes. 
 
11.3.6  Indication Panel 
LED  POWER  TIMER  QUIET  POWERFUL 
Color  Green  Orange  GREEN  RED 
Light ON  Operation ON  Timer setting ON  Quiet mode ON  Powerful mode ON 
Light OFF  Operation OFF  Timer setting OFF  Quiet mode OFF  Powerful mode OFF 
 
Note: 
●   If POWER LED blinks, the possible operation of the unit is operating mode judgment, or ON timer 
sampling. 
●  If Timer LED blinks, there is an abnormal operation occurs. 
11.3.7  Timer control 
Delay ON Timer can be set using remote controller, the unit with timer set will start operate earlier than the setting 
time. This is to provide a comfortable environment when reaching the set ON time. Seventy minutes before the set 
time for ON Timer or ON-OFF Timer setting, indoor ( at fan speed of Lo-) and outdoor fan motor start operate for 30 
seconds to determine the indoor intake air temperature and outdoor air temperature in order to judge the operation 
mode. From the above judgment, the decided operation will start operate earlier than the set time as shown below.