29
2. For Heating mode:
Note: The value of A, B, C, D will change according to the indoor temperature.
11.3.5 Automatic Restart Control
When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to
four minutes after power supply resumes.
11.3.6 Indication Panel
LED POWER TIMER QUIET POWERFUL
Color Green Orange GREEN RED
Light ON Operation ON Timer setting ON Quiet mode ON Powerful mode ON
Light OFF Operation OFF Timer setting OFF Quiet mode OFF Powerful mode OFF
Note:
If POWER LED blinks, the possible operation of the unit is operating mode judgment, or ON timer
sampling.
If Timer LED blinks, there is an abnormal operation occurs.
11.3.7 Timer control
Delay ON Timer can be set using remote controller, the unit with timer set will start operate earlier than the setting
time. This is to provide a comfortable environment when reaching the set ON time. Seventy minutes before the set
time for ON Timer or ON-OFF Timer setting, indoor ( at fan speed of Lo-) and outdoor fan motor start operate for 30
seconds to determine the indoor intake air temperature and outdoor air temperature in order to judge the operation
mode. From the above judgment, the decided operation will start operate earlier than the set time as shown below.