2. During heating operation, the indoor fan will run at the following speed when the compressor stops.
1 2 3 4 5 6 7 8
Comp
ON OFF
RE9PKE-3 540 460 540 460 540 460
RE12PKE-3
420 400 420 400 420 400
Fan Speed
(rpm)
Control by
piping
temperature
RE15PKE-3
420 400 420 400 420 400
Time
(Second)
20 100 20 100 20 100
3. Hot Start
When the heating operation starts, the indoor fan stops and the compressor runs with a certain frequency.
This is to prevent the cold airflow from blowing.
If the piping temperature rises to 19 , and the indoor fan speed varies with the indoor piping temperature, the hot
start control is stopped.
12.3.2 Overload Protection Control
Frequency of the compressor is determined by indoor piping temperature.