EasyManua.ls Logo

Panasonic CS-RE18GKE - User Manual

Panasonic CS-RE18GKE
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
© 2007 Panasonic HA Air-Conditioning (M) Sdn. Bhd.
(11969-T). All rights reserved. Unauthorized copying
and distribution is a violation of law.
Order No. MAC0701002C2
Air Conditioner
CS-RE18GKE CU-RE18GKE
CS-RE24GKE CU-RE24GKE
TABLE OF CONTENTS
PAGE PAGE
1 Safety Precautions----------------------------------------------- 3
2 Specifications ----------------------------------------------------- 5
2.1. CS-RE18GKE CU-RE18GKE ------------------------- 5
2.2. CS-RE24GKE CU-RE24GKE ------------------------- 7
3Features------------------------------------------------------------- 9
4 Location of Controls and Components ------------------10
4.1. Indoor Unit--------------------------------------------------10
4.2. Outdoor Unit -----------------------------------------------10
4.3. Remote Control -------------------------------------------10
5Dimensions--------------------------------------------------------11
5.1. Indoor Unit & Remote Control-------------------------11
5.2. Outdoor Unit -----------------------------------------------12
6 Refrigeration Cycle Diagram --------------------------------14
7 Block Diagram----------------------------------------------------15
7.1. CS-RE18GKE CU-RE18GKE ------------------------15
7.2. CS-RE24GKE CU-RE24GKE ------------------------16
8 Wiring Connection Diagram ---------------------------------17
8.1. CS-RE18GKE CU-RE18GKE------------------------ 17
8.2. CS-RE24GKE CU-RE24GKE------------------------ 18
9 Electronic Circuit Diagram----------------------------------- 19
9.1. CS-RE18GKE CU-RE18GKE------------------------ 19
9.2. CS-RE24GKA CU-RE24GKA------------------------ 21
10 Printed Circuit Board ------------------------------------------ 23
10.1. Indoor Unit ------------------------------------------------- 23
10.2. Indicator ---------------------------------------------------- 23
10.3. Outdoor Unit----------------------------------------------- 24
11 Installation Instruction ---------------------------------------- 25
11.1. Select The Best Location ------------------------------ 25
11.2. Indoor/Outdoor Unit Installation Diagram ---------- 25
11.3. Indoor Unit ------------------------------------------------- 26
11.4. Outdoor Unit----------------------------------------------- 29
12 Operation And Function-------------------------------------- 32
12.1. Basic Function -------------------------------------------- 32
12.2. Airflow Direction ------------------------------------------ 32

Table of Contents

Questions and Answers

  • C
    Crystal WhiteAug 16, 2025
    What to do if my Panasonic Air Conditioner has indoor high pressure protection?
    • D
      Darrell HuntAug 16, 2025
      If your Panasonic Air Conditioner is experiencing indoor high pressure protection issues, it might be due to a dirty air filter or a short circuit in the air circulation. Check these components to resolve the issue.
  • L
    lclarkAug 19, 2025
    Why is my Panasonic CS-RE18GKE Air Conditioner showing indoor heat exchanger anti-freezing protection?
    • R
      Richard GibsonAug 19, 2025
      If your Panasonic Air Conditioner is showing indoor heat exchanger anti-freezing protection, it could be caused by insufficient refrigerant or a dirty air filter. Make sure to check these potential causes.
  • C
    Charles MeadowsAug 22, 2025
    What causes IPM (power transistor) overheating protection in a Panasonic Air Conditioner?
    • S
      Sonya DeckerAug 22, 2025
      If the IPM (power transistor) is overheating in your Panasonic Air Conditioner, it may be due to excess refrigerant, improper heat radiation, or a faulty IPM (Power transistor).
  • M
    Madison AdkinsAug 25, 2025
    Why does my Panasonic Air Conditioner have outdoor compressor overheating protection?
    • D
      dana90Aug 25, 2025
      If your Panasonic Air Conditioner's outdoor compressor is overheating, it might be caused by insufficient refrigerant or a problem with the compressor itself.
  • B
    Brianna BellAug 27, 2025
    What causes total running current protection in a Panasonic CS-RE18GKE?
    • N
      Nancy DuncanAug 27, 2025
      If your Panasonic Air Conditioner is experiencing total running current protection, it could be due to excess refrigerant or improper heat radiation. Address these issues to resolve the problem.
  • M
    Michael BarnesAug 30, 2025
    What to do if my Panasonic CS-RE18GKE's outdoor compressor has abnormal revolution?
    • Z
      zbranchAug 30, 2025
      If your Panasonic Air Conditioner's outdoor compressor is experiencing abnormal revolution, the compressor itself may be the issue. Check the outdoor compressor.
  • P
    Patrick MeltonSep 1, 2025
    Why is there a refrigeration cycle abnormality in my Panasonic Air Conditioner?
    • V
      vincentgoodSep 1, 2025
      If there is a refrigeration cycle abnormality in your Panasonic Air Conditioner, it might be because there is no refrigerant, possibly due to a closed 3-way valve.
  • K
    Kathryn CarpenterSep 4, 2025
    What causes cooling/heating cycle changeover abnormality in Panasonic CS-RE18GKE?
    • R
      Russell HallSep 4, 2025
      If you're experiencing a cooling/heating cycle changeover abnormality with your Panasonic Air Conditioner, the issue might be with the 4-way valve or the V-coil. Check these components.
  • T
    Troy RodriguezSep 7, 2025
    What to do if the indoor fan motor mechanism is locked in my Panasonic CS-RE18GKE Air Conditioner?
    • P
      Pamela OrtizSep 7, 2025
      If the indoor fan motor mechanism is locked in your Panasonic Air Conditioner, the problem could be with the indoor PCB or the fan motor itself. Check these components.
  • M
    Melissa MunozSep 10, 2025
    What causes outdoor heat exchanger temperature sensor abnormality in Panasonic CS-RE18GKE Air Conditioner?
    • H
      hendricksrhondaSep 10, 2025
      If your Panasonic Air Conditioner displays an outdoor heat exchanger temperature sensor abnormality, the outdoor heat exchanger temperature sensor may be defective or disconnected.

Panasonic CS-RE18GKE Specifications

General IconGeneral
TypeSplit System
Cooling Capacity5.0 kW
InverterYes
Power Supply220-240V, 50Hz
Annual Energy Consumption (Cooling)350 kWh
RefrigerantR32
Indoor Unit Dimensions (W x H x D)919 x 290 x 206 mm
Outdoor Unit Dimensions (W x H x D)780 x 542 x 289 mm
Weight (Indoor Unit)9 kg
Weight (Outdoor Unit)28 kg
Energy Efficiency Ratio (EER)3.21 W/W