31
4. Cable connection to the power supply through knife switch (Disconnecting means).
• Connect the approved polychloroprene sheathed power supply cable (3 x 1.5 mm
2
) RE18GK, (3 x 4.0 mm
2
) RE24GK type
designation 245 IEC 57 or heavier cord to the terminal board, and connect the other end of the cable to knife switch
(Disconnecting means).
5. Select required direction and apply protective bushing provided in accessories to protect cables from sharp edges.
6. Once all wiring work has been completed, tie the wires and cord together with the binding strap so that they do not touch other
parts such as the compressor and pipes.
Note : Knife switch (Disconnecting means) should have minimum 3.5 mm contact gap.
• Secure the cable onto the control board with the holder (clamper).
• Power supply earth cable must connect to the left earth terminal.