6
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (80.6°F D.B.) and outdoor air temperature of 7°C D.B.
(44.6°F D.B.), 6°C W.B. (42.8°F W.B.)
Note
• Specifications are subject to change without notice for further improvement.
Heat Exchanger
Fin Material Aluminium (Pre coat) Aluminium (Blue coat)
Fin Type Slit Fin Corrugated Fin
Row x Stage x FPI 1 x 15 x 19 2 x 34 x 16
Size (W x H x L) mm 810 x 315 x 25.4 36.4 x 714 x 803.2:831.9
Air Filter Type
Material P. P. Honey Comb —
Style One-Touch —
Item Unit
Power Source (Phase, Voltage, Cycle)
øSingle
V 230
Hz 50
Input Power
Cooling W 1.65k (215 ~ 2.05k)
Heating W 1.79k (245 ~ 2.65k)
*Annual consumption W 825
Starting Current A 8.3
Running Current
Cooling A 7.5
Heating A 8.1
Power Factor
Cooling % 96
Heating % 96
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord
Number of core —
Length m (ft) —
Thermostat —
Protection Device —
ITEM UNIT INDOOR UNIT OUTDOOR UNIT