EasyManua.ls Logo

Panasonic CS-RE9QKE - User Manual

Panasonic CS-RE9QKE
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Български Português Italiano Español Français English
F569459
Operating Instructions
Air Conditioner
2-9
Thank you for purchasing this Panasonic Air conditioner.
Installation instructions attached.
Before operating the unit, read these operating
instructions thoroughly and keep them for future
reference.
Comment utiliser l’appareil
Climatiseur
10-17
Nous vous remercions d’avoir porté votre choix sur un
climatiseur Panasonic.
Instructions d’installation jointes.
Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son
intégralité et conservez-le pour toute référence ultérieure.
Instrucciones de funcionamiento
Climatizador de aire
18-25
Muchas gracias por elegir una unidad de aire
acondicionado Panasonic.
Incluye instrucciones de instalación.
Antes de utilizar la unidad, sírvase leer atentamente estas
instrucciones de funcionamiento y conservarlas como
futuro elemento de consulta.
Istruzioni di funzionamento
Condizionatore d’aria
26-33
Grazie per aver acquistato un climatizzatore Panasonic.
Istruzioni d’installazione allegate.
Prima di utilizzare l’unità si prega di leggere attentamente
le istruzioni e di conservare questo opuscolo per potervi
fare riferimento in futuro.
Instruções de funcionamento
Aparelho de ar condicionado
34-41
Obrigado por adquirir o Ar Condicionado da Panasonic.
Instruções de Instalação fornecido.
Antes de ligar a unidade, leia cuidadosamente este
manual de utilização e guarde-o para futura referência.
Инструкции за работа
Климатик
42-49
Благодарим Ви, че закупихте климатик Panasonic.
Приложени са инструкции за монтаж.
Преди да задействате климатика, прочетете
внимателно инструкциите за употреба и ги запазете за
бъдещи справки.
Operating Instructions
Air Conditioner
Model No.
Indoor Unit Outdoor Unit
CS-RE9QKE
CS-RE12QKE
CS-RE15QKE
CS-UE9QKE
CS-UE12QKE
CS-YE9QKE
CS-YE12QKE
CU-RE9QKE
CU-RE12QKE
CU-RE15QKE
CU-UE9QKE
CU-UE12QKE
CU-YE9QKE
CU-YE12QKE
(RE/UE9/12QKE)
(YE9/12QKE)

Other manuals for Panasonic CS-RE9QKE

Questions and Answers

  • J
    jessica03Aug 19, 2025
    What to do if the Panasonic CS-RE9QKE remote control is not working?
    • B
      Brittney WilliamsAug 20, 2025
      If the remote control for your Panasonic Air Conditioner isn't working, start by inserting the batteries correctly. If that doesn't solve the issue, try replacing the batteries with new ones.
  • E
    Eric HallAug 22, 2025
    How to improve the efficiency of HEAT/COOL mode on my Panasonic CS-RE9QKE?
    • M
      Michael MorrisAug 22, 2025
      If your Panasonic Air Conditioner isn't operating efficiently in HEAT/COOL mode, make sure you've set the temperature correctly. Additionally, close all doors and windows, clean or replace the filters, and clear any obstructions at the air inlet and outlet vents.
  • T
    Teresa VasquezAug 25, 2025
    Why is my Panasonic CS-RE9QKE not receiving the signal from the remote control?
    • D
      Donna RobinsonAug 25, 2025
      If your Panasonic Air Conditioner isn't receiving the signal from the remote control, ensure that there are no obstructions blocking the transmitter. Also, be aware that certain fluorescent lights may interfere with the signal.
  • D
    ddominguezAug 26, 2025
    Why does my Panasonic CS-RE9QKE show a total running current protection error?
    • M
      Michael GilesAug 26, 2025
      Total running current protection can occur due to several reasons. It might be due to compressor failure, which requires checking and repairing the compressor. It could also be caused by a defective outdoor unit PCB or a defective inverter main circuit electrolytic capacitor, in which case, replacing the PCB or capacitor is necessary. Finally, excessive refrigerant can also trigger this protection; therefore, refrigerant levels should be checked.
  • D
    David GambleAug 28, 2025
    How to fix indoor/outdoor abnormal communication in Panasonic Air Conditioner?
    • R
      Robert WilliamsAug 28, 2025
      If your Panasonic Air Conditioner displays an indoor/outdoor communication error, it could be due to a faulty indoor or outdoor unit PCB, which necessitates checking the wire terminal or the main PCB. Another cause might be a signal transmission error because of wiring issues between the indoor and outdoor units; in this case, inspect and repair the wiring.
  • D
    Dr. Scott PrestonAug 30, 2025
    What to do if my Panasonic Air Conditioner shows indoor/outdoor capacity rank mismatched error?
    • C
      carolyn38Aug 30, 2025
      Indoor/outdoor capacity rank mismatch in your Panasonic Air Conditioner can occur due to several reasons. It might be because of wrong models interconnected, so you should check model compatibility. It could also be caused by wrong indoor unit or outdoor unit PCBs mounted, defective PCBs, wrong wiring, or broken wires in the connection. Inspect and verify PCB installations, replace faulty PCBs, correct wiring errors, or repair disconnections to resolve the issue.
  • J
    Javier JonesSep 1, 2025
    Why is the indoor fan motor locked in my Panasonic CS-RE9QKE Air Conditioner?
    • D
      Dawn RichSep 1, 2025
      If your Panasonic Air Conditioner's indoor fan motor is locked, it could be due to a short circuit or broken wire inside the fan motor winding, broken fan motor lead wires, Hall IC malfunction, or a faulty indoor unit PCB. Repair the fan motor or wire, inspect and repair the lead wires, replace the Hall IC, or replace the PCB.
  • S
    sandrareedSep 3, 2025
    What causes outdoor current transformer abnormality in Panasonic Air Conditioner?
    • P
      Peter TaylorSep 3, 2025
      If your Panasonic Air Conditioner shows an outdoor current transformer abnormality, it may be due to a lack of gas, a broken CT (current transformer), or a broken outdoor PCB. To address this, check refrigerant levels, replace the CT, or inspect/replace the PCB.
  • A
    Anthony CobbSep 5, 2025
    What does compressor temperature sensor abnormality mean on my Panasonic CS-RE9QKE?
    • J
      Joshua GoodwinSep 6, 2025
      If your Panasonic Air Conditioner displays a compressor temperature sensor abnormality, it could be due to a faulty connector connection, a faulty sensor, or a faulty PCB. Check and reconnect the connector, replace the sensor, or replace the PCB to resolve this.
  • D
    Douglas YatesSep 8, 2025
    What does indoor intake air temperature sensor abnormality mean on my Panasonic CS-RE9QKE Air Conditioner?
    • E
      Erica PetersonSep 8, 2025
      If your Panasonic Air Conditioner displays an indoor intake air temperature sensor abnormality, it could be due to a faulty connector connection, a faulty sensor, or a faulty PCB. Check and reconnect the connector, replace the sensor, or replace the PCB to resolve this.

Summary

Quick guide

Basic Air Conditioner Operation

How to start, stop, and select modes for the unit.

Safety Precautions

Indoor and Outdoor Unit Safety

Safety guidelines for the indoor and outdoor units.

Power Supply Safety

Safety warnings regarding the power supply cord.

How to Use the Air Conditioner

Selecting Operation Modes

Details on AUTO, HEAT, COOL, and DRY operating modes.

Cleaning and Maintenance

Troubleshooting and Error Codes

Normal Symptoms and Causes

Common occurrences that are not malfunctions and their causes.

Non-Serviceable Conditions

Conditions that require professional service and dealer consultation.

Panasonic CS-RE9QKE Specifications

General IconGeneral
TypeAir conditioner indoor unit
Multi-splitNo
Product colorWhite
Hose length (max)15 m
Inverter technologyYes
Refrigerating mediumR410A
Dehumidifying capacity1.5 l/h
Air conditioner functionsCooling, Dehumidifying, Heating
Seasonal efficiency rating (cooling) (SEER)6.10
Seasonal efficiency rating (heating) (SCOP) (Average heating season)4.00
Current16 A
AC input voltage230 V
Energy efficiency class (cooling)A++
Annual energy consumption (cooling)143 kWh
Hourly energy consumption (cooling)0.67 kWh
Hourly energy consumption (heating)0.8 kWh
Energy efficiency class (heating) (Average heating season)A+
Annual energy consumption (heating) (Average heating season)840 kWh
Indoor unit typeWall-mountable
Indoor unit depth214 mm
Indoor unit width870 mm
Indoor unit height290 mm
Indoor unit weight9000 g
Indoor units quantity1
Cooling airflow (indoor unit)702 m³/h
Heating airflow (indoor unit)768 m³/h
Indoor unit noise level (high speed)57 dB