Operating Instructions
Air Conditioner
Model No.
Indoor Unit Outdoor Unit
CS-RE9PKE-3 CU-RE9PKE-3 CS-
RE12PKE-3 CU-RE12PKE-3 CS-
RE15PKE-3 CU-RE15PKE-3
Operating Instructions
2-9
Thank you for purchasing Panasonic Air Conditioner.
Before operating the unit, read these operating instructions
thoroughly and keep them for future reference.
Installation Instructions attached for authorized dealer or
specialist.
Mode d’emploi
10-17
Nous vous remercions d’avoir porté votre choix sur un
climatiseur Panasonic.
Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son
intégralité et conservez-le pour toute référence ultérieure.
Instructions d’installation ci-jointes pour un revendeur ou
spécialiste agréé.
Manual de Instrucciones
18-25
Muchas gracias por elegir una unidad de aire acondicionado
Panasonic.
Antes de utilizar la unidad, sírvase leer atentamente estas
instrucciones de funcionamiento y conservarlas como futuro
elemento de consulta.
Instrucciones de Instalación adjuntas para el distribuidor
autorizado o especialista.
Istruzioni di funzionamento
26-33
Grazie per aver acquistato un climatizzatore Panasonic.
Prima di utilizzare l’unità si prega di leggere attentamente le
istruzioni e di conservare questo opuscolo per potervi fare
riferimento in futuro.
Istruzioni sull’installazione allegate per il concessionario
autorizzato o specialista.
Manual de Utilização
34-41
Obrigado por adquirir o Ar Condicionado da Panasonic.
Antes de ligar a unidade, leia cuidadosamente este manual
de utilização e guarde-o para futura referência.
Instrões de Instalão em anexo para representante
autorizado ou especialista.
Инструкции за работа
42-49
Благодарим Ви, че закупихте климатик Panasonic.
Преди да задействате климатика, прочетете внимателно
инструкциите за употреба и ги запазете за бъдещи
справки
Приложени са указания за монтаж,
предназначени за използване от официален
представител или специалист.
F568946

Other manuals for Panasonic CS-RE9PKE-3

Questions and Answers

  • B
    Brenda WeissAug 20, 2025
    Why does my Panasonic CS-RE9PKE-3 Air Conditioner outdoor unit emits water/steam?
    • F
      fischerjustinAug 20, 2025
      The emission of water or steam from your Panasonic Air Conditioner's outdoor unit is due to condensation or evaporation occurring on the pipes.
  • D
    Donna AndersonAug 22, 2025
    Why is my Panasonic CS-RE9PKE-3 Air Conditioner remote control not working?
    • G
      Gregory CraigAug 22, 2025
      If the Panasonic Air Conditioner remote control isn't working, start by ensuring the batteries are inserted correctly. If the display is dim or the transmission signal is weak, try replacing the batteries with new ones.
  • K
    kayla90Aug 25, 2025
    How to improve cooling/heating efficiency in my Panasonic Air Conditioner?
    • J
      Jordan SmithAug 25, 2025
      If your Panasonic Air Conditioner's COOL/HEAT mode isn't working efficiently, make sure to set the temperature correctly and close all doors and windows. Additionally, clean or replace the filters and clear any obstructions at the air inlet and outlet vents.
  • D
    Diana FrankAug 27, 2025
    What to do if my Panasonic CS-RE9PKE-3 Air Conditioner does not receive the signal from the remote control?
    • K
      Kathy McbrideAug 27, 2025
      If your Panasonic Air Conditioner isn't receiving the signal from the remote control, ensure that nothing is obstructing the receiver. Note that certain fluorescent lights may interfere with the signal transmitter; please consult an authorized dealer for assistance.
  • M
    Matthew TrevinoAug 28, 2025
    What causes Indoor/Outdoor abnormal communication in a Panasonic CS-RE9PKE-3?
    • J
      jennifershieldsAug 28, 2025
      Abnormal communication between the indoor and outdoor units can be caused by the connecting cable or issues with the indoor/outdoor PCB.
  • N
    ngreenAug 30, 2025
    What causes Indoor fan motor mechanism lock in Panasonic Air Conditioner?
    • N
      nmeadowsAug 30, 2025
      A locked indoor fan motor mechanism can be caused by the indoor PCB or the fan motor itself.
  • M
    mbensonSep 1, 2025
    Why does my Panasonic Air Conditioner operation is delayed a few minutes after restarting?
    • S
      steven17Sep 1, 2025
      The delay you're experiencing after restarting your Panasonic Air Conditioner is a protection mechanism for the unit’s compressor.
  • M
    Meghan DoyleSep 3, 2025
    Why does my Panasonic Air Conditioner unit operate automatically when power is resumed after a power failure?
    • J
      James SmithSep 3, 2025
      The automatic operation of your Panasonic Air Conditioner after a power failure is due to the Auto Restart function of the unit.
  • P
    Patty TaylorSep 5, 2025
    Why is mist emerging from my Panasonic Air Conditioner indoor unit?
    • J
      Jordan SpencerSep 5, 2025
      The mist coming from your Panasonic Air Conditioner's indoor unit is a condensation effect caused by the cooling process.
  • S
    Sherri RothSep 7, 2025
    Why does my Panasonic CS-RE9PKE-3 make a cracking sound during operation?
    • J
      johnaguilarSep 7, 2025
      The cracking sound you hear during the operation of your Panasonic Air Conditioner is caused by the expansion and contraction of the unit due to temperature changes.

Summary

Quick Guide

Inserting the Batteries

Guide on how to insert batteries into the remote control.

Timer Setting

Instructions for setting the timer function on the remote control.

Basic Operation

Steps for basic operation, including mode and temperature selection.

Safety Precautions

Warning and Caution Symbols

Explains the meaning of warning and caution symbols used in the manual.

Indoor and Outdoor Unit Safety

Safety guidelines for operating the indoor and outdoor units.

Remote Control Safety

Safety measures related to the use of the remote control.

Power Supply Safety

Precautions concerning the electrical power supply and connection.

How to Use

Basic Unit Operation

Instructions for turning the unit on/off, setting temperature, and fan speed.

Operation Modes and Settings

Details on selecting operation modes (AUTO, HEAT, COOL, DRY) and special settings.

Airflow Direction Control

Guidance on adjusting horizontal and vertical airflow directions.

Timer and Auto Functions

How to use the timer functions and the auto OFF/ON button.

Operation Conditions

Recommended temperature ranges for cooling and heating operations.

Cleaning and Maintenance

Indoor Unit Cleaning

Instructions for cleaning the indoor unit's front panel and air filters.

Seasonal Inspection

Checks to perform before seasonal use or after extended non-use.

Troubleshooting Guide

Common Symptoms and Causes

Lists common symptoms that are not malfunctions and their causes.

Before Calling for Service

Checks to perform before contacting a service dealer for issues.

Error Code Retrieval

Instructions on how to retrieve error codes using the remote control.

Product Specification

Technical Specifications

Detailed technical data including power, capacity, noise level, and dimensions.

Notes on Specifications

Important notes regarding standby power, piping length, and air filters.

Information

Disposal of Electrical and Battery Waste

Information on the collection and disposal of old equipment and used batteries.

Panasonic CS-RE9PKE-3 Specifications

General IconGeneral
Indoor unit typeWall-mountable
Indoor unit weight8000 g
Indoor units quantity1
Cooling airflow (indoor unit)750 m³/h
Heating airflow (indoor unit)666 m³/h
Indoor unit dimensions (WxDxH)848 x 213 x 290 mm
TypeAir conditioner indoor unit
Ionizer-
Remotely operatedYes
Refrigerating mediumR410A
Cooling capacity (max)- BTU/h
Dehumidifying capacity1.4 l/h
Timer duration (maximum)12 h
Air conditioner functionsCooling, Dehumidifying, Heating
Cooling capacity in watts (max)3000 W
Cooling capacity in watts (min)900 W
Heating capacity in watts (max)4100 W
Cooling energy efficiency (EER, W/W)3.57
Heating energy efficiency (COP, W/W)4.02
Seasonal efficiency rating (cooling) (SEER)5.6
Seasonal efficiency rating (heating) (SCOP) (Average heating season)3.4
Noise level (low speed)22 dB
Noise level (high speed)58 dB
Noise level (medium speed)42 dB
Power requirements230V, 16A
Annual energy consumption156 kWh

Related product manuals