EasyManua.ls Logo

Panasonic CS-S12TKV

Panasonic CS-S12TKV
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
145
17.1.2 CS-S12TKV CU-S12TKV
Cooling Characteristic
o Room temperature: 27°C (DBT), 19°C (WBT)
o Operation condition: High fan speed
o Piping length: 5.0 m
o Compressor Frequency = Fc
13.200
13.400
13.600
13.800
14.000
14.200
14.400
14.600
14.800
15.000
30 31 32 33 34 35 36 37 38 39 40 41 42 43
Indoor Discharge
Air Temperature (°C)
Outdoor Air Temperature (°C)
220
2.800
2.900
3.000
3.100
3.200
3.300
3.400
3.500
30 31 32 33 34 35 36 37 38 39 40 41 42 43
Cooling
Capacity (kW)
Outdoor Air Temperature (°C)
3.800
3.900
4.000
4.100
4.200
4.300
4.400
4.500
4.600
4.700
30 31 32 33 34 35 36 37 38 39 40 41 42 43
Current
(A)
Outdoor Air Temperature (°C)
0.960
0.970
0.980
0.990
1.000
1.010
30 31 32 33 34 35 36 37 38 39 40 41 42 43
Gas Side Piping
Pressure (MPa)
Outdoor Air Temperature (°C)

Table of Contents