Multi Zone Submittal Data
Indoor: CS-S9NKUW-1
Wall Mounted Air Conditioner's
Job Name: Approval:
Location: Date:
Engineer: Construction:
Submitted to: Unit #:
Submitted by: Drawing #:
Reference:
Power
V
/PH/Hz 230/208/1/60 Refrigeran
t
Circuit Ampacity (A) 15 Control Electric Expansion Valve
Fuse Size, Max. (A) 15 Connection
Line Size (in. O.D. Discharge) 1/4"
Indoor Unit Line Size (in. O.D. Suction) 3/8"
Fan type Cross Flow
No. Speeds 5 Dimensions (in.) Height Width Depth
RPM (High) Indoor Unit (Uncrated) 11-7/16" 34-9/32" 8-1/16"
Motor Output (W) 40
CFM (QLo/Lo/Me/Hi/SHi) 199/239/321/400/442 Weight Indoor
Indoor Sound Rating (Hi) (dB-A) 40 Net (lbs.) 20
Coil Type Aluminum Fin & Copper Tube Shipping (lbs.)
Fin Type - Pipe Type Slit Plate - Inner Rifled
Rows - F.P.I 2-19
Face Area (sq.ft) Cooling
Drain Connection Size (in.) 5/8" Total Capacity (BTU/H)
SEER 17.5
Features Dehumidification (Pints/H) 1.3
Wireless Remote Controller Standard
Wired Remote Controller ( CZ-RD516C ) Optional Operating Range
Controls Microprocessor Indoor Air Intake Temp.
Remote Controller LCD Wireless Type, Temp, Sensor Built In Cooling Maximum 90F DB/74F WB
Temperature Control IC Thermostat Minimum 60F DB/52F WB
Air Louver (Horizontal) Manual
(Vertical) Automatic
Power Failure Automatic Restart Built-In
Self-Diagnosis Built-In
Air Filter Washable, Anti-Mold
R410A
Flare
10200
Performance Data @ ARI Standard Conditions (230/208V)

Other manuals for Panasonic CS-S9NKUW-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-S9NKUW-1 and is the answer not in the manual?

Panasonic CS-S9NKUW-1 Specifications

General IconGeneral
RefrigerantR410A
TypeSplit System
EER (Cooling)11.0
HSPF (Heating)9.0
Cooling Capacity9, 000 BTU/h

Related product manuals