EasyManua.ls Logo

Panasonic CS-TZ35WKEW - User Manual

Panasonic CS-TZ35WKEW
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Deutsch Español Français English
ACXF55-27151
Operating Instructions
Air Conditioner
Model No.
Indoor Unit Outdoor Unit
CS-TZ20WKEW
CS-TZ25WKEW
CS-TZ35WKEW
CS-TZ42WKEW
CS-TZ50WKEW
CS-RZ20WKEW
CS-RZ25WKEW
CS-RZ35WKEW
CS-RZ50WKEW
CS-MTZ16WKE
Single Split
CU-TZ20WKE
CU-TZ25WKE
CU-TZ35WKE
CU-TZ42WKE
CU-TZ50WKE
CU-RZ20WKE
CU-RZ25WKE
CU-RZ35WKE
CU-RZ50WKE
CS-TZ60WKEW
CS-TZ71WKEW
Single Split
CU-TZ60WKE
CU-TZ71WKE
Multi Split
CU-2Z35TBE
CU-2Z41TBE
CU-2Z50TBE
CU-3Z52TBE
CU-3Z68TBE
CU-4Z68TBE
CU-4Z80TBE
CU-5Z90TBE
CU-2TZ41TBE
CU-2TZ50TBE
CU-3TZ52TBE
Operating Instructions
Air Conditioner
2-25
Before operating the unit, please read these operating
instructions thoroughly and keep them for future reference.
The included Installation Instructions should be kept and read
by the installer before installation.
Remote control is packaged in the indoor unit and removed
by the installer before installation.
Comment utiliser l’appareil
Climatiseur
26-49
Avant d’utiliser l’appareil, veuillez lire ce mode d’emploi dans
son intégralité et conservez-le pour toute référence ultérieure.
Le manuel d’installation inclus doit être conservé et lu par
l’installateur avant l’installation.
La télécommande est emballée dans l’unité intérieure et
retirée par l’installateur avant l’installation.
Instrucciones de funcionamiento
Climatizador de aire
50-73
Antes de utilizar la unidad, sírvase leer atentamente estas
instrucciones de funcionamiento y conservarlas para futuras
consultas.
El instalador debe guardar y leer las Instrucciones de
instalación incluidas antes de la instalación.
El mando a distancia viene embalado en la unidad interior y
debe ser retirado por el instalador antes de la instalación.
Bedienungsanleitung
Klimagerät
74-97
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese
Bedienungsanleitung aufmerksam durch und bewahren Sie
sie als künftige Referenz auf.
Das mitgelieferte Installationshandbuch sollte aufbewahrt und
vor der Installation vom Installateur gelesen werden.
Die Fernbedienung ist im Innengerät verpackt und wird vor
der Installation durch den Installateur entfernt.
ACXF55-27151.indb 1ACXF55-27151.indb 1 12/2/2019 10:07:38 AM12/2/2019 10:07:38 AM

Other manuals for Panasonic CS-TZ35WKEW

Questions and Answers

  • M
    Michael PorterSep 10, 2025
    Why does my room have a peculiar odour when using Panasonic Air Conditioner?
    • S
      Sara JacksonSep 10, 2025
      If the room has a peculiar odour when your Panasonic Air Conditioner is running, this may be due to damp smell emitted by the wall, carpet, furniture or clothing.
  • M
    Monica OrtegaAug 22, 2025
    What to do if Panasonic Air Conditioner unit does not work?
    • J
      Jacob BakerAug 22, 2025
      If your Panasonic Air Conditioner unit isn't working, check if the circuit breaker has tripped. Also, verify whether any timers have been set.
  • C
    Chelsea YoungAug 25, 2025
    What to do if Panasonic CS-TZ35WKEW remote control does not work?
    • J
      jeremiah38Aug 25, 2025
      If the remote control for your Panasonic Air Conditioner isn't working, first ensure that the batteries are inserted correctly. If the display is dim or the transmission signal is weak, try replacing the batteries.
  • S
    sellersnatalieAug 26, 2025
    Why is the TIMER indicator always on on my Panasonic Air Conditioner?
    • E
      Emily EvansAug 26, 2025
      If the TIMER indicator on your Panasonic Air Conditioner is always on, it means the timer setting repeats daily once set.
  • S
    Stacy BestAug 27, 2025
    Why does my Panasonic Air Conditioner outdoor unit emit water/steam?
    • M
      mollyfrederickAug 27, 2025
      If the outdoor unit of your Panasonic Air Conditioner emits water or steam, it is due to condensation or evaporation occurring on the pipes.
  • A
    Ashley JohnsonAug 29, 2025
    Why is my Panasonic Air Conditioner noisy during operation?
    • A
      Arthur LangAug 29, 2025
      If your Panasonic Air Conditioner is noisy during operation, check whether the unit has been installed at an incline. Also, make sure that the front panel is closed properly.
  • R
    Rebekah KhanSep 18, 2025
    Why does Panasonic CS-TZ35WKEW Wireless LAN LED stay ON during unit turn OFF?
    • E
      Elizabeth CarpenterSep 18, 2025
      If the Wireless LAN LED stays ON during unit turn OFF of your Panasonic Air Conditioner, it means the unit’s LAN connection with the router is activated.
  • D
    Douglas KiddSep 12, 2025
    Why is my Panasonic CS-TZ35WKEW Air Conditioner making a cracking sound?
    • C
      Courtney TaylorSep 12, 2025
      If you hear a cracking sound during the operation of your Panasonic Air Conditioner, it is due to temperature changes causing the expansion or contraction of the unit.
  • J
    Julie GarciaSep 8, 2025
    Why does airflow continue after Panasonic CS-TZ35WKEW Air Conditioner has stopped?
    • J
      Jessica JacksonSep 8, 2025
      If airflow continues from your Panasonic Air Conditioner even after operation has stopped, this is due to the extraction of remaining heat from the indoor unit, which takes a maximum of 30 seconds.
  • K
    Kevin MolinaSep 5, 2025
    Why does Panasonic CS-TZ35WKEW Air Conditioner indoor fan stop during heating?
    • O
      owheelerSep 5, 2025
      The indoor fan of your Panasonic Air Conditioner might stop occasionally during heating operation to avoid unintended cooling effect.

Summary

Quick Guide

Basic Operation

Safety Precautions

General Warnings and Cautions

Key safety warnings and cautions for unit operation.

R32 Refrigerant Safety

Specific safety measures for R32 flammable refrigerant.

Installation and Servicing Safety

Safety guidelines for installation and servicing.

Work Safety and Ignition Control

Safety during work and avoiding ignition sources.

Equipment and Electrical Safety Checks

Safety checks for refrigerating equipment and electrical devices.

Component Repair and Leak Detection Safety

Safety for component repair and leak detection.

Leak Detection and Evacuation Procedures

Leak detection methods and system evacuation.

Refrigerant Charging and Decommissioning

Safe procedures for refrigerant charging and decommissioning.

How to Use

Cleaning Instructions

Troubleshooting

Panasonic CS-TZ35WKEW Specifications

General IconGeneral
TypeSplit System
Cooling TechnologyInverter
Cooling Capacity3.5 kW
Heating Capacity4.0 kW
RefrigerantR32
Compressor TypeRotary
Power Supply220-240V, 50Hz
Coefficient of Performance (COP)4.0
Outdoor Unit Dimensions (W x H x D)780 x 542 x 289 mm
Indoor Unit Weight8 kg
Indoor Unit Noise Level19 dB(A)