119
o Press TEMP increment or decrement button to choose No. 5.
o Press Timer increment or decrement button to select desired temperature low limit of set temperature for
HEAT mode.
o Press Timer Set button to confirm low limit selection.
o Press TEMP increment or decrement button to choose No. 6.
o Press Timer decrement or increment button to select desired temperature high limit of set temperature for
HEAT mode.
o Press Timer Set button to confirm low limit selection.
Memorize new
Low1 range
Normal display mode
Press SW to enter customer zone &
Press SW to comfirm selection
Use SW or SW to change Low1 range
SET
i) Display latest set temp (Low1).
ii) After reset, Low1 = 16°C (by default)
Range = 16°C ~ [High1]
No code transmission
SET
Press
SW’s to choose function 5
Memorize new
High1
range
Normal display mode
Press SW to enter customer zone &
Press SW to comfirm selection
Use SW or SW to change High1 range
SET
i) Display latest set temp (High1).
ii) After reset, High1 = 30°C (by default)
Range = [Low1] ~ 30°C
No code transmission
SET
Press
SW’s to choose function 6