15 CAPACITY AND POWER CONSUMPTION
Q
QQ
Q
PERFORMANCE DATA
COOLING PERFORMANCE
Model Cooling capacities are based conditions.
CS-W50BD3P
O Indoor temp. 27°C D.B. 19°C W.B.
O Outdoor temp. 35°C D.B.
O Standard air volume 40 m
3
/min
O External Static Pressure (49Pa)
Cooling capacity
12.5kW
Entering Temperature Air Entering Condenser (°C D.B.)
Air 25°C 30°C 35°C 40°C 45°C
Temperature TC SHC IPT TC SHC IPT TC SHC IPT TC SHC IPT TC SHC IPT
D.B. W.B. kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW
17 13.0 8.72 4.22 12.5 8.63 4.46 11.8 8.35 4.80 10.9 7.94 5.17 10.1 7.58 5.38
23 19 13.7 7.28 4.47 13.3 7.32 4.73 12.6 7.20 5.09 11.8 6.95 5.48 11.0 6.74 5.64
22 15.0 6.15 4.83 14.6 6.28 5.11 13.9 6.27 5.49 13.0 6.13 5.92 12.3 6.01 6.04
17 12.9 10.2 4.20 12.4 10.0 4.46 11.6 9.7 4.79 10.8 9.18 5.15 10.1 8.81 5.35
25 19 13.8 8.94 4.47 13.3 8.90 4.74 12.6 8.67 5.10 11.7 8.31 5.48 11.0 8.05 5.66
22 15.0 7.35 4.83 14.5 7.42 5.12 13.8 7.33 5.51 12.4 6.82 5.92 12.2 6.97 5.99
17 12.7 12.1 4.18 12.2 11.9 4.46 11.5 11.5 4.79 10.7 10.7 5.12 10.1 10.1 5.32
27 19 13.8 10.5 4.47 13.3 10.3 4.76 12.5 10.0 5.12 11.6 9.53 5.47 11.0 9.24 5.68
22 15.0 8.54 4.83 14.5 8.54 5.14 13.7 8.37 5.53 11.8 7.42 5.91 12.2 7.94 6.02
17 12.7 12.0 4.16 12.2 11.9 4.41 11.6 11.6 4.72 10.8 10.8 5.04 10.3 10.3 5.22
29 19 13.7 12.6 4.44 13.3 12.5 4.72 12.5 12.0 5.04 11.7 11.5 5.38 11.1 11.1 5.57
22 14.9 10.0 4.90 14.4 9.90 5.20 13.7 9.70 5.55 12.4 9.03 5.93 12.2 9.14 6.09
17 12.7 12.0 4.14 12.2 11.9 4.39 11.6 11.6 4.67 10.9 10.9 4.98 10.3 10.3 5.15
32 19 13.7 13.0 4.43 13.3 12.9 4.69 12.6 12.6 4.99 11.8 11.8 5.32 11.2 11.2 5.50
22 14.9 12.4 4.94 14.4 12.2 5.23 13.6 11.9 5.57 12.8 11.4 5.94 12.2 11.1 6.14
HEATING PERFORMANCE
Model Heating capacities are based conditions
CS-W50BD3P
O Indoor temp. 20°C D.B.
O Outdoor temp. 7°C D.B. 6°C W.B.
O Standard air volume 40 m
3
/min
O External Static Pressure (49Pa)
Heating capacity
14.0kW
Inlet Air Outdoor Temperature (°C W.B.)
External Static Pressure (Pa)
Air Volume (m
3
/min)
Entering Air
Dry Bulb (°C)
-6°C 0°C 6°C 12°C
H.C. IPT H.C. IPT H.C. IPT H.C. IPT
49Pa 40m
3
/min
15 9.9 3.69 12.0 4.20 14.7 4.86 17.5 5.68
20 9.24 4.45 11.3 4.45 14.0 5.12 16.7 5.99
25 8.54 4.10 10.6 4.71 13.3 5.38 16.0 6.10