8.11. Quiet Operation
•
The Quiet operation is to provide quiet cooling/heating operation condition compare to normal operation.
(Cooling and Soft Dry Operation condition)
•
Once the Quiet Mode is set at the remote control, Quiet Mode LED illuminates. The sound level will reduce either around
2 dB(A) for Lo fan speed or 3 dB(A) for Hi/Me fan speed against the present sound level operation.
•
Dew formation become severe at Quiet Lo cool, therefore Quiet Lo cool is operated only 1hr 30 min (1hr QLo, 30 min QLo
+ 80 rpm). After that, it goes back to QLo+160 (However Quiet LED remains on).
•
Manual Fan Speed:-
−
RPM control during Lo cool
−
RPM control during Hi & Me cool
•
Auto Fan Speed:-
−
Cooling operation
−
Soft Dry operation
35