12.5. Auto OFF/ON Button
The Auto OFF/ON Button (behind the front grille) is used to operate the air conditioner if remote control is misplaced or
mulfunctioning.
Forced cooling operation is possible by pressing the Auto OFF/ON Button for more than 5s where beep sound is heard then
release the button.
User able to select remote control transmission code and toggle remote control signal receiving sound under various setting
mode.
To enter various setting mode:
Press the Auto OFF/ON Button continuously for 5s (beep sound is heard) and release.
Within 20s, press the Auto OFF/ON Button continuously for 5s again (2 beep sound is heard) and release.
Various setting mode has limit up to 20s. Then return to normal operation.
12.5.1. Toggle Remote Control Signal Receiving Sound
Under various setting mode, press the Auto OFF/ON Button to toggle the remote control sound.
Short beep: Turn ON remote control signal receiving sound.
Long beep: Turn OFF remote control signal receiving sound.
After Auto OFF/ON Button is pressed, the 20s counter for various setting mode is restarted.
12.5.2. Select Remote Control Transmission Code
There are 4 types of remote control transmission code could be selected and stored in EEPROM of indoor unit. The indoor unit
will only operate when received signal with same transmission code from remote control. This could prevent signal interference
when there are 2 or more indoor unit installed nearby together.
To change remote control transmission code, short or open jumpers at the remote control printed circuit board.
Under various setting mode, after select the transmission code combination of remote control, press any button of remote
control to transmit a signal to indoor unit. The transmission code will be stored in EEPROM.
After signal is received, the various setting mode is cancelled and return to normal operation.