EasyManua.ls Logo

Panasonic CS-XE7LKEW - Page 121

Panasonic CS-XE7LKEW
185 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
121
16.4.28. F97 (Compressor Overheating)
Malfunction Decision Conditions
During operation of cooling and heating, when compressor tank temperature data (112eC) is detected by the compressor tank
temperature sensor.
Malfunction Caused
Faulty compressor tank temperature sensor
2/3 way valve closed
Refrigerant shortage (refrigerant leakage)
Faulty outdoor unit PCB
Faulty compressor
Troubleshooting

Table of Contents

Other manuals for Panasonic CS-XE7LKEW

Related product manuals