14.3.4. Low Temperature Compressor Oil Return Control (E7 ~ 15LK)
In heating operation, if the outdoor temperature falls below -10°C when compressor starts, the compressor frequency will be
regulated up to 600 seconds.
14.3.5. Cold Draught Prevention Control
When indoor pipe temperature is low, cold draught operation starts where indoor fan speed will be reduced.
14.3.6. Deice Operation
When outdoor pipe temperature and outdoor air temperature is low, deice operation start where indoor fan motor and outdoor fan
motor stop and operation LED blinks.