EasyManua.ls Logo

Panasonic CS-YS12PKV User Manual

Panasonic CS-YS12PKV
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
© Panasonic Corporation 2013
Order No: PAPAMY1307113CE
Indoor Unit Outdoor Unit
CS-PS9PKV
CS-PS12PKV
CS-PS18PKV
CS-PS24PKV
CU-PS9PKV
CU-PS12PKV
CU-PS18PKV
CU-PS24PKV
Destination
Panama
Columbia
Ecuador
Caribbean Islands
Trinidad & Tobago
PRECAUTION OF LOW TEMPERATURE
In order to avoid frostbit, be assured of no refrigerant leakage during the installation or repairing of refrigerant circuit.
WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to
service or repair the products dealt with in this service information by anyone else could result in serious injury or death.

Table of Contents

Questions and Answers:

Panasonic CS-YS12PKV Specifications

General IconGeneral
BrandPanasonic
ModelCS-YS12PKV
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Precautions

Specification

Location of Controls and Components

Indoor Unit

Identifies and illustrates controls and indicators on the indoor unit.

Outdoor Unit

Identifies and illustrates components of the outdoor unit.

Remote Control

Details the buttons and functions of the remote control.

Dimensions

Indoor Unit

Provides detailed measurements for indoor unit models.

Outdoor Unit

Provides detailed measurements for outdoor unit models.

Refrigeration Cycle Diagram

CS-PS9PKV CU-PS9PKV CS-PS12PKV CU-PS12PKV

Illustrates the refrigeration cycle for specific indoor/outdoor unit models.

CS-PS18PKV CU-PS18PKV CS-PS24PKV CU-PS24PKV

Illustrates the refrigeration cycle for other indoor/outdoor unit models.

Block Diagram

CS-PS9PKV CU-PS9PKV

Shows the electrical block diagram for specific unit models.

CS-PS12PKV CU-PS12PKV

Shows the electrical block diagram for specific unit models.

CS-PS18PKV CU-PS18PKV

Shows the electrical block diagram for specific unit models.

CS-PS24PKV CU-PS24PKV

Shows the electrical block diagram for specific unit models.

Wiring Connection Diagram

Indoor Unit

Details wiring connections for the indoor unit.

Outdoor Unit

Details wiring connections for the outdoor unit.

Electronic Circuit Diagram

Indoor Unit

Illustrates the electronic circuit for the indoor unit.

Outdoor Unit

Illustrates the electronic circuit for the outdoor unit.

Printed Circuit Board

Indoor Unit

Shows physical layout of indoor unit PCBs.

Outdoor Unit

Shows physical layout of outdoor unit PCBs.

Installation Instruction

Select the Best Location

Guidelines for choosing the optimal installation site.

Indoor Unit

Step-by-step instructions for indoor unit installation.

Outdoor Unit

Step-by-step instructions for outdoor unit installation.

Operation Control

Basic Function

Explains the core functions and inverter control.

Indoor Fan Motor Operation

Details how the indoor fan motor operates.

Outdoor Fan Motor Operation

Details how the outdoor fan motor operates.

Airflow Direction

Explains vertical and horizontal airflow adjustments.

Timer Control

Describes setting ON and OFF timers.

Random Auto Restart Control

Explains the auto restart function after power interruption.

Indication Panel

Describes the meaning of indicator LEDs.

ECONAVI & AUTO COMFORT Operation

Details the intelligent operation modes.

Protection Control

Restart Control (Time Delay Safety Control)

Explains the compressor restart delay safety feature.

30 Seconds Forced Operation

Describes the minimum compressor operation time.

Total Running Current Control

Details protection against excessive running current.

IPM (Power Transistor) Prevention Control

Explains protection against IPM overheating and peak current.

Low Pressure Prevention Control (Gas Leakage Detection)

Describes protection against low refrigerant pressure.

Compressor Tank Temperature Rise Protection Control

Details protection against compressor tank temperature rise.

Low Frequency Protection Control 1

Explains protection against low compressor frequency operation.

Low Frequency Protection Control 2

Details the second low frequency protection control.

Outdoor Air Temperature Control

Explains compressor frequency regulation based on outdoor temp.

Cooling Overload Control

Details protection against cooling overload conditions.

Freeze Prevention Control

Explains protection against indoor freezing.

Freeze Prevention Control 2

Details the second freeze prevention control.

Dew Prevention Control

Describes control to prevent dew formation.

Odor Cut Control

Explains the odor reduction feature.

Servicing Mode

Auto Off/On Button

Explains how to use the Auto Off/On button for service modes.

Remote Control Button

Details functions of SET and RESET buttons on the remote.

Troubleshooting Guide

Refrigeration Cycle System

Guides on diagnosing issues using refrigeration cycle parameters.

Breakdown Self Diagnosis Function

Explains how to access and interpret error codes.

Error Code Table

Lists error codes and their meanings/locations.

Troubleshooting Flowchart

Provides flowcharts for diagnosing specific error codes.

Disassembly and Assembly Instructions

CS-PS9/12PKV

Step-by-step guide for disassembling indoor units.

CS-PS18/24PKV

Step-by-step guide for disassembling indoor units.

Technical Data

Operation Characteristics

Provides graphs of cooling performance vs. outdoor temp/piping length.

Exploded View and Replacement Parts List

Indoor Unit

Exploded views and parts list for indoor units.

Outdoor Unit

Exploded views and parts list for outdoor units.

Related product manuals