21.3.2 CS-Z50TKEW CU-Z50TKE CS-Z71TKEW CU-Z71TKE CS-XZ50TKEW CU-Z50TKE
Cooling Capacity
Correction Factor
Heating Capacity
Correction Factor
Pipe Length (m)
Pipe Length (m)
0.95
0.97
0.99
1.01
1.03
234567891011121314151617181920212223242526272829303132
0.96
0.97
0.97
0.98
0.98
0.99
0.99
1.00
1.00
1.01
1.01
234567891011121314151617181920212223242526272829303132
Note: The graphs show the factor after added right amount of additional refrigerant.
Maximum piping length for Z50TKE is 20 meters.
Maximum piping length for Z71TKE is 30 meters.