EasyManua.ls Logo

Panasonic CS-Z20TKEW - Page 56

Panasonic CS-Z20TKEW
197 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
56
12.2.5.2 Connecting the Piping to Outdoor
Decide piping length and then cut by using pipe cutter.
Remove burrs from cut edge.
Make flare after inserting the flare nut (locate at valve)
onto the copper pipe. Align center of piping to valve
and then tighten with torque wrench to the specified
torque as stated in the table.
Do not overtighten, overtightening may cause gas leakage.
Piping size Torque
6.35 mm (1/4") [18 N•m (1.8 kgf•m)]
9.52 mm (3/8") [42 N•m (4.3 kgf•m)]
12.7 mm (1/2") [55 N•m (5.6 kgf•m)]
15.88 mm (5/8") [65 N•m (6.6 kgf•m)]
19.05 mm (3/4") [100 N•m (10.2 kgf•m)]
12.2.5.3 Connecting the Piping to Outdoor Multi
Decide piping length and then cut by using pipe cutter.
Remove burrs from cut edge. Make flare after
inserting the flare nut (locate at valve) onto the copper
pipe. Align center of piping to valve and then tighten
with torque wrench to the specified torque as stated in
the table.
Connection pipe
(female side)
Auxiliary pipe
(male side)
Flare Nut
Hall Union
Liquid side
* For Gas side piping please refer table and diagram below
Outdoor Multi Combination Model
Pipe size
(refer to
diagram)
R32 Model R410A Model
CS-Z20***,
CS-XZ20***,
CS-Z25***,
CS-XZ25***,
CS-Z35***,
CS-XZ35***
CU-2Z35***,
CU-2Z41***,
CU-2Z50***,
CU-3Z52***,
CU-3Z68***,
CU-4Z68***,
CU-4Z80***,
CU-5Z90***
CU-2E12***,
CU-2E15***,
CU-2E18***,
CU-3E18***,
CU-3E23***,
CU-4E23***,
CU-4E27***,
CU-5E34***
CS-Z42***,
CS-Z50***,
CS-XZ50***
CU-2Z50***,
CU-3Z52***,
CU-3Z68***,
CU-4Z68***,
CU-4Z80***,
CU-5Z90***
CU-2E18***,
CU-3E18***,
CU-3E23***,
CU-4E23***,
CU-4E27***,
CU-5E34***
(CZ-MA1P)
CS-Z71*** CU-4Z80***,
CU-5Z90***
CU-4E27***,
CU-5E34***
(CZ-MA2P) &
(CZ-MA3P)
Hall Union
Connection pipe
(female side)
Auxiliary pipe
(male side)
Flare Nut
Hall Union
Packing
Connection pipe
(female side)
Auxiliary pipe
(male side)
Pipe size reducer (CZ-MA1P)
Flare Nut
Auxiliary pipe
(male side)
(Outdoor)
Auxiliary pipe
(male side)
(Indoor)
Hall Union
Hall Union
Packing
Packing Connection pipe
(female side)
Pipe size expander
(CZ-MA2P)
Flare Nut
Pipe size reducer
(CZ-MA3P)
Gas side
AMP Air Conditioning