1 Features 2
2 Functions
3
3 Product Specifications
6
4 Dimensions
14
5 Refrigeration Cycle Diagram
16
6 Block Diagram
18
7 Wiring Diagram
22
8 Operation Details
26
9 Operating Instructions
34
10 Installation Instructions
39
© 2002 Matsushita Industrial Corp. Sdn. Bhd.
(11969-T). All rights reserved. Unauthorized copying
and distribution is a violation of law.
CS-V9BKPG CU-2V14BKP5G
CS-V9BKPG CU-2V18BKP5G
CS-V9BKPG CU-3V20BKP5G
CS-V7BKPG CU-2V19BKP5G
CS-V12BKPG
11 Installation and Servicing Air Conditioner Using R410A 49
12 Servicing Information
60
13 Troubleshooting Guide
64
14 Technical Data
66
15 Exploded View
72
16 Replacement Parts List
73
17 Exploded View
74
18 Replacement Parts List
75
19 Exploded View
76
20 Replacement Parts List
77
Multi-Split Air Conditioner
CONTENTS
Page Page
Order No. MAC0205021C2

Questions and Answers

  • A
    Adam AlexanderAug 4, 2025
    Why Panasonic CU-2V14BKP5G Air Conditioner does not operate?
    • L
      Lisa SteeleAug 4, 2025
      The air conditioner might not be operating due to several reasons. Please check the following: Has the circuit breaker been tripped? Is the timer being used correctly? Is the installation work slanted? Is the front grille closed properly? Has the temperature been set incorrectly? Are the filters dirty? Are the intake or outlet vents of the outdoor unit obstructed? Are all windows and doors closed?
  • S
    Stephanie KimAug 8, 2025
    Why does my Panasonic CU-2V14BKP5G outdoor unit emits water or steam?
    • B
      Bridget SalazarAug 8, 2025
      During COOL/DRY operation, moisture in the air condenses into water on the cool surface of outdoor unit piping, which causes dripping. This is normal.
  • W
    Wanda VelezAug 12, 2025
    What to do if Panasonic CU-2V14BKP5G has been restarted, but does not operate for 3 minutes?
    • A
      april94Aug 12, 2025
      This is a normal protective measure for your Panasonic Air Conditioner. Please wait until the air conditioner begins to operate; this delay protects the unit.
  • J
    Joseph BrownAug 17, 2025
    What to do if it seems that fog is coming out from the Panasonic CU-2V14BKP5G?
    • A
      Alicia GreenAug 17, 2025
      The fog-like appearance is due to condensation that occurs when the airflow from the air conditioner cools the room. This is a normal phenomenon.
  • R
    Randy WatsonAug 20, 2025
    Why does Panasonic Air Conditioner indoor fan stops occasionally during Automatic Airflow setting?
    • M
      michael43Aug 21, 2025
      This happens to remove smell emitted by the surroundings.
  • A
    Alisha MitchellAug 25, 2025
    Why the room has a peculiar odour when Panasonic CU-2V14BKP5G is working?
    • M
      Michelle MurphyAug 26, 2025
      The odor may be a damp smell emitted by the wall, carpet, furniture, or clothing in the room.
  • S
    smithchristineAug 29, 2025
    Why can I hear a sound like water flowing in my Panasonic Air Conditioner?
    • D
      Dorothy RogersAug 29, 2025
      This sound is the sound of refrigerant flowing inside the air conditioner.

Summary

Features

Product Specifications

Operation Details

Cooling Mode Operation

Explains the operating principles and safety controls during cooling mode.

Soft Dry Mode Operation

Details the functionality and controls specific to the soft dry operation mode.

Vertical Airflow Direction Control

Details auto and manual control of vertical airflow direction.

Installation Instructions

Safety Precautions

Outlines critical safety warnings and guidelines for installation.

Indoor Unit Installation

Covers selecting the location and mounting the indoor unit.

Outdoor Unit Installation

Details the process for selecting the location and installing the outdoor unit.

Installation and Servicing Air Conditioner Using R410 A

About R410 A Refrigerant

Provides information on R410A refrigerant characteristics and safety.

Tools for Installing; Servicing Refrigerant Piping

Lists the necessary tools for working with R410A refrigerant piping.

Refrigerant Piping Work

Details procedures for piping materials, processing, and connections.

Servicing Information

Indoor Electronic Controllers Removal Procedures

Step-by-step guide for removing indoor electronic controller components.

Indoor Fan Motor and Cross Flow Fan Removal Procedures

Details the process for removing the indoor fan motor and fan.

Troubleshooting Guide

Refrigeration Cycle System

Guides on diagnosing issues related to the refrigeration cycle.

Diagnosis Methods of a Malfunction of a Compressor

Explains how to identify compressor faults and symptoms.

Technical Data

Operation Characteristics

Presents performance data graphs for various operating conditions.

Replacement Parts List

Electronic Circuit Diagram

Panasonic CU-2V14BKP5G Specifications

General IconGeneral
BrandPanasonic
ModelCU-2V14BKP5G
CategoryAir Conditioner
LanguageEnglish

Related product manuals