1 Features 2
2 Functions
3
3 Product Specifications
6
4 Dimensions
14
5 Refrigeration Cycle Diagram
16
6 Block Diagram
18
7 Wiring Diagram
22
8 Operation Details
26
9 Operating Instructions
34
10 Installation Instructions
39
© 2002 Matsushita Industrial Corp. Sdn. Bhd.
(11969-T). All rights reserved. Unauthorized copying
and distribution is a violation of law.
CS-V9BKPG CU-2V14BKP5G
CS-V9BKPG CU-2V18BKP5G
CS-V9BKPG CU-3V20BKP5G
CS-V7BKPG CU-2V19BKP5G
CS-V12BKPG
11 Installation and Servicing Air Conditioner Using R410A 49
12 Servicing Information
60
13 Troubleshooting Guide
64
14 Technical Data
66
15 Exploded View
72
16 Replacement Parts List
73
17 Exploded View
74
18 Replacement Parts List
75
19 Exploded View
76
20 Replacement Parts List
77
Multi-Split Air Conditioner
CONTENTS
Page Page
Order No. MAC0205021C2

Questions and Answers

  • S
    Sydney CastroAug 4, 2025
    Why Panasonic CU-2V19BKP5G does not operate?
    • K
      Kristi KramerAug 4, 2025
      The air conditioner might not be operating due to several reasons. Please check the following: Has the circuit breaker been tripped? Is the timer being used correctly? Is the installation work slanted? Is the front grille closed properly? Has the temperature been set incorrectly? Are the filters dirty? Are the intake or outlet vents of the outdoor unit obstructed? Are all windows and doors closed?
  • C
    christian55Aug 8, 2025
    Why does my Panasonic CU-2V19BKP5G Air Conditioner outdoor unit emits water or steam?
    • M
      Michael JacksonAug 8, 2025
      During COOL/DRY operation, moisture in the air condenses into water on the cool surface of outdoor unit piping, which causes dripping. This is normal.
  • J
    johnsonsethAug 12, 2025
    What to do if Panasonic Air Conditioner has been restarted, but does not operate for 3 minutes?
    • C
      Caroline BernardAug 12, 2025
      This is a normal protective measure for your Panasonic Air Conditioner. Please wait until the air conditioner begins to operate; this delay protects the unit.
  • D
    Donna HernandezAug 17, 2025
    What to do if it seems that fog is coming out from the Panasonic Air Conditioner?
    • M
      Melissa RodriguezAug 17, 2025
      The fog-like appearance is due to condensation that occurs when the airflow from the air conditioner cools the room. This is a normal phenomenon.
  • C
    christopher90Aug 21, 2025
    Why does Panasonic CU-2V19BKP5G indoor fan stops occasionally during Automatic Airflow setting?
    • V
      Victor CookAug 21, 2025
      This happens to remove smell emitted by the surroundings.
  • M
    Mrs. Holly YoungAug 25, 2025
    Why the room has a peculiar odour when Panasonic Air Conditioner is working?
    • S
      Susan DavisAug 26, 2025
      The odor may be a damp smell emitted by the wall, carpet, furniture, or clothing in the room.
  • D
    Dylan TaylorAug 29, 2025
    Why can I hear a sound like water flowing in my Panasonic CU-2V19BKP5G?
    • T
      Theresa GilbertAug 29, 2025
      This sound is the sound of refrigerant flowing inside the air conditioner.

Summary

Product Features

Unit Functions and Remote Control

Product Specifications

Unit Dimensions

Refrigeration Cycle Diagram

System Block Diagram

Wiring Diagrams

Operation Details

Cooling Mode Operation

Details cooling operation, safety controls, and anti-dew formation.

Soft Dry Mode Operation

Explains soft dry mode, fan speed, and time controls.

Sleep Mode Auto Operation

Provides comfortable room temp. during sleep, adjusts temp. and airflow.

Powerful Mode Operation

Obtains setting temp. quickly, auto fan speed, vertical airflow, and time limit.

Economy Mode Operation

Saves power by increasing set temp. and auto airflow.

Operating Instructions and Safety

Safety Precautions

Warns about electrical shock, injury, and property damage.

Installation Precautions

Advises against DIY installation, stresses proper grounding and drainage.

Operation Precautions

Advises proper use, avoiding wet hands, and proper power cord usage.

How to Operate

Guide on starting operation, setting modes, temperature, and fan speed.

Convenience Operation

Details Sleep, Economy, and Powerful modes for comfort and efficiency.

Installation Instructions

Required tools for Installation Works

Lists necessary tools for installation.

Safety Precautions

Lists warnings and cautions for installation safety.

CAUTION

Notes potential electrical shock and fire hazards.

ATTENTION

Advises on location selection, power connection, refrigerant handling, and installation work.

Indoor;Outdoor Unit Installation Diagram

Illustrates the installation layout for indoor and outdoor units.

CONNECTING THE PIPING

Guides on connecting refrigerant piping to indoor and outdoor units.

EVACUATION OF THE EQUIPMENT

Procedure for removing air from the system using a vacuum pump.

R410 A Refrigerant Installation and Servicing

About R410 A Refrigerant

Explains R410A properties, safety, and comparison with R22.

Safety Measure When Installing; Receiving Refrigerant Piping

Safety precautions for handling R410A refrigerant.

Brazing

Explains brazing techniques and precautions for preventing oxidation.

Servicing Information and Procedures

Indoor Electronic Controllers Removal Procedures

Steps to remove electronic controllers and receivers.

Indoor Fan Motor and Cross Flow Fan Removal Procedures

Steps to remove indoor fan motor and cross flow fan.

Troubleshooting Guide

Refrigeration cycle system

Analyzes refrigeration cycle performance based on pressure and temperature.

Diagnosis methods of a malfunction of a compressor

How to diagnose compressor faults like insufficient compression or locked compressor.

Technical Data and Performance Charts

Thermostat characteristics

Graphs showing thermostat behavior for Cooling and Soft Dry modes.

Sensor Characteristics

Graphs showing thermistor and temperature sensor characteristics.

OLP Characteristics

Graphs illustrating Overload Protector trip current vs. ambient temperature.

Exploded View Diagrams

Replacement Parts Lists

Electronic Parts List

Electronic Circuit Diagrams

How to use electronic circuit diagram

Guidance on interpreting circuit diagrams and voltage measurements.

REMOTE CONTROL

Details the remote control circuit and transmission code settings.

Panasonic CU-2V19BKP5G Specifications

General IconGeneral
BrandPanasonic
ModelCU-2V19BKP5G
CategoryAir Conditioner
LanguageEnglish

Related product manuals