EasyManua.ls Logo

Panasonic CU-2Z35TBE User Manual

Panasonic CU-2Z35TBE
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Español Français English
Operating Instructions
Air Conditioner
ACXF55-22540
Model No.
Indoor Unit Outdoor Unit
CS-Z20VKEW
CS-Z25VKEW
CS-Z35VKEW
CS-Z42VKEW
CS-Z50VKEW
CS-Z71VKEW
CS-XZ20VKEW
CS-XZ25VKEW
CS-XZ35VKEW
CS-XZ50VKEW
CS-MZ16VKE
Single Split (R32)
CU-Z20VKE
CU-Z25VKE
CU-Z35VKE
CU-Z42VKE
CU-Z50VKE
CU-Z71VKE
Multi Split (R410A)
CU-3E18PBE
CU-4E23PBE
CU-4E27PBE
CU-5E34PBE
CU-2E12SBE
CU-2E15SBE
CU-2E18SBE
CU-3E23SBE
Multi Split (R32)
CU-2Z35TBE
CU-2Z41TBE
CU-2Z50TBE
CU-3Z52TBE
CU-3Z68TBE
CU-4Z68TBE
CU-4Z80TBE
CU-5Z90TBE
Operating Instructions
Air Conditioner
2-41
Before operating the unit, please read these operating
instructions thoroughly and keep them for future reference.
The included Installation Instructions should be kept and read
by the installer before installation.
Remote control is packaged in the indoor unit and removed
by the installer before installation.
Comment utiliser l’appareil
Climatiseur
42-77
Avant d’utiliser l’appareil, veuillez lire ce mode d’emploi dans
son intégralité et conservez-le pour toute référence ultérieure.
Le manuel d’installation inclus doit être conservé et lu par
l’installateur avant l’installation.
La télécommande est emballée dans l’unité intérieure et
retirée par l’installateur avant l’installation.
Instrucciones de funcionamiento
Climatizador de aire
78-113
Antes de utilizar la unidad, sírvase leer atentamente estas
instrucciones de funcionamiento y conservarlas para futuras
consultas.
El instalador debe guardar y leer las Instrucciones de
instalación incluidas antes de la instalación.
El mando a distancia viene embalado en la unidad interior y
debe ser retirado por el instalador antes de la instalación.

Other manuals for Panasonic CU-2Z35TBE

Questions and Answers:

Panasonic CU-2Z35TBE Specifications

General IconGeneral
Cooling Capacity3.5 kW
Heating Capacity4.0 kW
Power Supply220-240 V, 50 Hz
RefrigerantR32
Noise Level (Outdoor Unit)48 dB

Summary

Operating Instructions

Quick Guide

Inserting the Batteries

Step-by-step guide to insert batteries into the remote control for operation.

Clock Setting

Instructions on how to set the clock on the remote control for accurate timer functions.

Basic Operation

Starting and Stopping Operation

Instructions on how to turn the air conditioner on and off using the remote control.

Selecting Operation Mode

Guide on choosing the desired operating mode (AUTO, HEAT, COOL, DRY) for comfort.

Setting Temperature

How to adjust the desired temperature using the remote control buttons.

Safety Precautions

General Warnings for Units

Important warnings regarding installation, handling, and potential hazards for indoor and outdoor units.

Remote Control Safety

Safety guidelines for using and storing the remote control, including battery precautions.

Network Adaptor Safety

Precautions related to the network adaptor, including proximity to medical equipment.

Power Supply Safety

Safety measures for power cords, outlets, and preventing electrical hazards.

Cautionary Measures for Units

Cautions for cleaning, placement, and general unit operation to prevent damage or injury.

Remote Control Cautions

Specific cautions for remote control usage, like battery types and long-term storage.

Network Adaptor Cautions

Cautions for network adaptor installation and operation, including power supply and timer settings.

Flammable Refrigerant Warning

Warning about R32 refrigerant being flammable and the risk of fire if leaked.

Installation and Operation Safety

Safety requirements for unit installation location and ventilation to prevent hazards.

Precautions for R32 Refrigerant

Installation and Service Tools

Specifics on installation work, piping, and tools required for R32 refrigerant.

Refrigerant Handling and Personnel

Requirements for trained personnel, refrigerant recovery, and safety measures for handling flammable refrigerants.

Personnel Qualification and Training

Requirements for personnel knowledge, training, and understanding of refrigerant regulations.

Installation Space and Pipework

Guidelines for installation space, pipework protection, and compliance with regulations.

Servicing Guidelines

Service Personnel Requirements

Qualifications and responsibilities of trained personnel performing servicing on the unit.

Work Procedures and Safety

Safety precautions and procedures for working on systems with flammable refrigerants.

Refrigerant Leak Detection

Methods and equipment for checking the presence of refrigerant and detecting leaks safely.

Fire Extinguisher Availability

Requirement for fire extinguishing equipment during servicing operations.

Ignition Source Control

Rules for eliminating ignition sources when working with flammable refrigerants.

Ventilation Requirements

Ensuring adequate ventilation during servicing to disperse released refrigerant safely.

Refrigerating Equipment Checks

Checks for electrical components, refrigerant charge, ventilation, and equipment markings during servicing.

Electrical Device Checks

Safety checks for electrical components, including capacitor discharge and earth bonding.

Sealed Component Repairs

Procedures for repairing sealed components, ensuring electrical isolation and leak detection.

Intrinsically Safe Component Repair

Guidelines for repairing intrinsically safe components in potentially hazardous environments.

Cabling Checks

Ensuring cabling is protected from wear, corrosion, and environmental effects.

Flammable Refrigerant Detection

Prohibiting ignition sources when searching for refrigerant leaks and using appropriate detectors.

Acceptable Leak Detection Methods

Approved methods for detecting refrigerant leaks, including sensitivity and calibration requirements.

Refrigerant Removal and Evacuation

Procedures for safely removing and evacuating refrigerant from the system during repairs.

Refrigerant Charging Procedures

Steps for charging the system with refrigerant, including contamination prevention and leak testing.

Decommissioning Procedures

Steps for safely decommissioning the unit, including refrigerant recovery and electrical isolation.

Equipment Labelling Requirements

Guidelines for labelling de-commissioned equipment and indicating flammable refrigerant presence.

Refrigerant Recovery Procedures

Detailed steps for safe recovery of refrigerant, including cylinder use, equipment checks, and oil draining.

System Overview

Network Adaptor Specification

Technical specifications for the Network Adaptor, including model, voltage, and wireless standards.

How to Use

Adjusting Airflow Direction

Instructions on how to control the direction of airflow using the remote control.

Adjusting Fan Speed

Guide on setting the fan speed for optimal cooling and noise reduction.

Powerful/Quiet Mode

How to activate powerful cooling or quiet operation modes for specific needs.

nanoe X Functionality

Explains the nanoe X feature for air purification, deodorization, and skin moisturization.

MILD DRY Operation

How to use the MILD DRY mode to reduce air dryness during COOL mode.

Sleeping Comfort Mode

How to activate sleep mode for comfortable sleeping with automatic temperature adjustment.

Setting ON/OFF Timers

Guide on setting the ON and OFF timers for automatic unit operation.

Operating Temperature Ranges

Recommended temperature settings for HEAT and COOL modes to save energy.

Connecting to Network

Steps to establish a wireless connection between the air conditioner and the home network.

Panasonic Comfort Cloud App Installation

Instructions for downloading and installing the Panasonic Comfort Cloud app on smartphones.

Creating Panasonic ID

Guide for new users to create a Panasonic ID for app registration and control.

App Setup: Adding New Device

Process for registering a new air conditioner device within the Panasonic Comfort Cloud app.

Setting Wireless Network Connection

Step-by-step guide to set up the network connection using the remote control and app.

Network Connection via WPS (Method 1)

Detailed steps to connect the air conditioner to the router using the WPS mode.

Network Connection via AP Mode (Method 2)

Detailed steps to connect the air conditioner using the Access Point (AP) mode.

Selecting Router SSID and Password

Steps to select the Wi-Fi network SSID and enter the password for connection.

Registering Air Conditioner and Setting Password

Guide to select the air conditioner model and set a password for registration.

Registration Completion and App Usage

Finalizing registration, naming the unit, and accessing app features like energy monitoring.

Network Adaptor Q&A

Initial Setup Issues

Answers to common questions regarding app installation and initial unit connection.

Wireless Connection Problems

Troubleshooting tips for unstable wireless signals and checking signal strength.

Other Network Adaptor Settings

Procedures for replacing routers, smartphones, control boards, or transferring unit data.

To Learn More

Operation Modes Explained

Detailed explanation of AUTO, HEAT, COOL, and DRY operation modes for single and multi-split systems.

Energy Saving Temperature Settings

Recommended temperature settings for HEAT and COOL modes to save energy.

Air Flow Direction Control

How airflow direction behaves in different modes (COOL/DRY, HEAT, MILD DRY).

Auto Restart Functionality

Explanation of the auto restart feature after a power failure, and its limitations with timers.

Cleaning Instructions

Indoor Unit Cleaning

How to clean the indoor unit's front panel and body with recommended materials.

Air Filter Cleaning

Instructions for cleaning the air filters, including washing, drying, and replacement.

Outdoor Unit and Drain Pipe Cleaning

How to clean the outdoor unit and ensure the drain pipe is clear of blockages.

Troubleshooting Guide

Common Operational Symptoms

Explanations for normal operational symptoms that may appear as malfunctions.

Pre-Service Checks

Checks to perform before calling for servicing, covering operation, noise, and remote control issues.

Remote Control Troubleshooting

Steps to take if the remote control is missing, malfunctioning, or indicators are too bright.

Seasonal Inspection and Non-Use Procedures

Guidelines for seasonal checks after extended non-use and preparing for long periods of inactivity.

Non-Serviceable Conditions

Conditions requiring professional service, such as abnormal noise or electrical issues.

Error Code Retrieval

Diagnostic Display and Error Codes

List of diagnostic codes and their corresponding abnormalities or protection controls for troubleshooting.

Product Information

Equipment Disposal and Battery Recycling

Information on responsible collection and disposal of old equipment and used batteries, especially in the EU.

Firmware Update Capability

Details on how the product automatically updates its firmware via the internet.

Software Licensing Details

Information regarding the software licenses, including open-source components and their terms.

Copyright and Software Licenses

Software Acknowledgements

Lists software used, including third-party and open-source components, with relevant licenses.

WPA Supplicant License Terms

Specific license terms for the WPA Supplicant software component.

Free RTOS License Terms

Details on the FreeRTOS license, including its modifications and exceptions.

FreeRTOS GPL Exception

Exception text for the FreeRTOS GNU General Public License, defining terms for combining modules.

GNU GPL Terms and Conditions

The full terms and conditions of the GNU General Public License Version 2.0.

Program Distribution Conditions

Conditions and requirements for distributing the Program and its derivative works under the GPL.

Warranty Disclaimer and Liability Limitation

Disclaimer of warranty and limitation of liability for the software provided.

Declaration of Conformity (DOC)

Biocidal Product Information

States that the air conditioner uses a biocidal product for air purification.

Related product manuals