Time Delay Safety Control
Starting Current Control
Anti-Freezing Control
Compressor Reverse Rotation Protection Control
Anti-Dew Formation Control
Automatic Fan Speed Mode
8.2. Soft Dry Mode Operation
The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and
then Soft Dry operation will start.
During Soft Dry operation, the Indoor Fan will operate at SLo speed.
The operation will be switched on and off for up to 10 minutes ON and 6 minutes OFF. Once Soft Dry operation is turned
off, it stops for 6 minutes.
Once the compressor stops, it will not start for 3 minutes during Cooling operation.
Same as Starting Current Control for Cooling Mode operation.
Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressor
stops.)
Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6 minutes waiting
is valid during compressor stops.)
Same as Anti-Dew Formation Control for Cooling Mode operation.
When Automatic Fan Speed is selected at Remote Control during Soft Dry operation.
Fan speed off and on at SLo speed.
Deodorizing Control.
28
CS-C9BKPG CU-2C14BKP5G / CS-C9BKPG CU-2C18BKP5G / CS-C9BKPG CU-3C20BKP5G / CS-C7BKPG CU-2C19BKP5G / CS-C12BKPG

Other manuals for Panasonic CU-3C20BKP5G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CU-3C20BKP5G and is the answer not in the manual?

Panasonic CU-3C20BKP5G Specifications

General IconGeneral
BrandPanasonic
ModelCU-3C20BKP5G
CategoryAir Conditioner
LanguageEnglish

Related product manuals