2. Sleep mode operation during heating operation
9.1.7. Timer Operation
Delay ON/OFF timer
·
In accordance with the air-conditioning load, the preparatory operation is performed so that the setting temperature will be
reached at the set time. The preparatory operation period is fixed as shown in the table below.
·
60 minutes before the set time, the indoor fan operates at SLo and outdoor fan operates for 30 seconds to sample the indoor
intake air temperature and outdoor air temperature in order to determine the starting time for preparatory operation. (Operation
LED blinks. Timer LED lights.)
·
The fan speed and air direction during the preparatory operation are based on the remote control settings (same as with normal
operation). However, at the automatic airflow setting, the fan speed setting is never raised above "Lo".
·
Timer setting method
Delay ON timer
Type Set time
Setting range 0 : 00 - 23 : 50
Increment 10 minutes
preparatory operation
●
Daily function
●
Delay OFF timer
Type Set time Single action
Setting range 0 : 00 - 23 : 50 1, 2,3, 5 or 7 hours
Interval 10 minutes ---
preparatory operation --- ---
·
During the preparatory operation, the compressor operation frequency and outdoor fan speed are reduced to reduce the noise
of the outdoor unit.
·
Delay ON timer preparatory operation time
32
CS-ME7CKPG / CS-ME10CKPG / CS-ME12CKPG / CS-ME14CKPG / CS-ME18CKPG / CU-2E15CBPG / CU-2E18CBPG / CU-3E23CBPG / CU-4E27CBPG