EasyManua.ls Logo

Panasonic CU-4Z71VBR User Manual

Panasonic CU-4Z71VBR
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Operating Instructions
Air Conditioner
nanoeX
Operating Instructions
Air Conditioner
Before operating the unit, please read these operating
instructions thoroughly and keep them for future reference.
Before installation, the installer should:
Read the Installation Instructions, then request the customer
keep them for future reference.
Remove the remote control packed with the indoor unit.
* Kindly consult authorised dealer for connectivity validity.
Model No.
Indoor Unit Outdoor Unit
Single Split
CS-Z50XKRW-1
CS-Z60XKRW
CS-Z60XKRW-1
CS-Z71XKRW
CS-Z80XKR
CU-Z50XKR-1
CU-Z60XKR
CU-Z60XKR-1
CU-Z71XKR
CU-Z80XKR
* Outdoor Unit
Multi Split
CU-4Z71VBR
CU-4Z80VBR
CU-5Z100VBR
ACXF55-31442
English
ACXF55-31442_SS1221-2_EN.indd 1ACXF55-31442_SS1221-2_EN.indd 1 29/11/2021 5:01:30 PM29/11/2021 5:01:30 PM

Questions and Answers:

Panasonic CU-4Z71VBR Specifications

General IconGeneral
Cooling Capacity7.1 kW
Heating Capacity8.2 kW
Energy Efficiency Ratio (EER)3.21
Power Supply220-240V, 50Hz
RefrigerantR32
Coefficient of Performance (COP)3.61
TypeMulti-Split
Indoor Unit Dimensions (W x H x D)Varies by unit model
Weight (Indoor Unit)Varies by unit model
Noise Level (Indoor)Varies by unit model

Summary

Quick Guide

Basic Operation

Safety Precautions

Indoor and Outdoor Unit Safety

Safety guidelines for the unit's indoor and outdoor components.

Remote Control Safety

Safety precautions for the remote control.

Power Supply Safety

Safety measures for the unit's power supply and electrical connections.

R32 Refrigerant Precautions

Specific safety guidelines for handling R32 refrigerant.

Installation Safety

Guidelines and precautions for the unit's installation.

Servicing Safety

Procedures for safe servicing by trained personnel.

Refrigerant Leak Detection

Procedures for checking and detecting refrigerant leaks.

Fire Prevention

Measures to prevent fire hazards during operation.

Ignition Source Control

Guidelines for managing ignition sources near the unit.

Component Repair Safety

Safety for repairing unit components.

Leak Detection Methods

Acceptable methods for detecting refrigerant leaks.

Refrigerant Handling Procedures

Procedures for refrigerant removal, charging, and decommissioning.

Refrigerant Recovery and Labelling

Best practices for refrigerant recovery and equipment labelling.

How to Use

Troubleshooting

How to Retrieve Error Codes

Retrieving Error Codes

Steps to retrieve error codes using the remote control.

Error Code List

A list of diagnostic codes and their meanings.

Related product manuals