Why does mist emerge from my Panasonic CU-E12LKE indoor unit?
- LLeah MaxwellAug 31, 2025
Mist emerges from the indoor unit of your Panasonic Air Conditioner due to the condensation effect caused by the cooling process.
Why does mist emerge from my Panasonic CU-E12LKE indoor unit?
Mist emerges from the indoor unit of your Panasonic Air Conditioner due to the condensation effect caused by the cooling process.
Why does my Panasonic CU-E12LKE make a cracking sound during operation?
The cracking sound during operation of your Panasonic Air Conditioner is due to changes in temperature causing the expansion and contraction of the unit.
What to do if my Panasonic Air Conditioner does not receive the signal from the remote control?
If your Panasonic Air Conditioner isn't receiving the signal from the remote control, make sure the receiver isn't obstructed. Be aware that certain fluorescent lights may interfere with the signal transmitter; consult an authorized dealer if this is the case.
Why is my Panasonic CU-E12LKE noisy during operation?
If your Panasonic Air Conditioner is noisy during operation, check if the unit has been installed at an incline and ensure the front panel is closed properly.
What to do if my Panasonic CU-E12LKE Air Conditioner is not working efficiently?
If your Panasonic Air Conditioner's heating or cooling isn't working efficiently, try the following: ensure the temperature is set correctly, close all doors and windows, clean or replace the filters, and clear any obstructions at the air inlet and outlet vents.
Why does my Panasonic CU-E12LKE emit water or steam from the outdoor unit?
The water or steam emitted from the outdoor unit of your Panasonic Air Conditioner is due to condensation or evaporation occurring on the pipes.
What to do if my Panasonic Air Conditioner unit stops and the timer indicator blinks?
To address this issue, use the remote control to retrieve the error code: press for 5 seconds, then press until you hear a beep sound and note the error code. For certain errors, you may restart the unit with limited operation, indicated by 4 beeps during start-up. If the problem persists, turn the unit off and provide the error code to an authorized dealer.
What does it mean when the power indicator blinks during HEAT mode with no warm air supply in my Panasonic CU-E12LKE Air Conditioner?
If the power indicator blinks during HEAT mode and there's no warm air supply from your Panasonic Air Conditioner, the unit is likely in defrost mode and the AIR SWING is set to AUTO.
What does it mean when the timer indicator is always on in my Panasonic Air Conditioner?
If the timer indicator on your Panasonic Air Conditioner is always on, it means the timer setting repeats daily once set.
What to do if my Panasonic CU-E12LKE remote control does not work?
If the remote control for your Panasonic Air Conditioner isn't working, make sure the batteries are inserted correctly or replace weak batteries.
Cooling Capacity | 3.5 kW |
---|---|
Heating Capacity | 4.0 kW |
Power Supply | 220-240V, 50Hz |
Refrigerant | R410A |
Indoor Unit Dimensions (W x H x D) | 870 x 290 x 214 mm |
Weight (Indoor Unit) | 9 kg |
Operating Temperature (Heating) | -15°C to 24°C |
Operating Temperature (Cooling) | 43 °C |