163
Heating Characteristic
[Condition] Indoor temperature: 20/-°C
Remote condition: High fan speed, Heat 30°C
Comp. Hz: F
h
29.000
30.000
31.000
32.000
33.000
34.000
35.000
36.000
37.000
-5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10
Outdoor Air Temperature (°C)
Outlet Air
Tempeature (°C
)
230
2.800
3.300
3.800
4.300
4.800
5.300
-5-4-3-2-1012345678910
Outdoor Air Temperature (°C)
Heating
Capacity (kW)
4.300
4.500
4.700
4.900
5.100
5.300
5.500
-5-4-3-2-1012345678910
Outdoor Air Temperature (°C)
Current
(A)
1.900
2.100
2.300
2.500
2.700
-5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10
Outdoor Air Temperature (°C)
Gas Side Piping
Pressure (MPa
)