77
ECO NAVI stop conditions:
o When ECO NAVI button is pressed again.
o When unit is OFF by OFF/ON button.
o When unit is OFF when OFF TIMER activates.
o When unit is OFF by AUTO OFF/ON button at indoor unit.
o When POWERFUL, QUIET operation activates.
o When ◄► button is pressed.
AUTO COMFORT / ECO NAVI initialization
Initialize indication Human Activity Sensor
1 0 – 2 seconds
2 2 – 3 seconds
I
II
III
IV
3 3 – 70 seconds
Repeat Step I to IV
* Indicator ON, Indicator OFF
12.13.1 Human Activity Sensor
Area of human availability, activity level and absent is judged based on pulses by using 2 infrared sensors. The
internal setting temperature shift, fan speed and horizontal airflow direction are adjusted in order to provide
comfort environment while maintain the energy saving level.
AUTO COMFPRT / ECO NAVI initialization
Initialize indication Human Activity Sensor
1 0 – 2 seconds
2 2 – 3 seconds
I
II
III
IV
3 3 – 70 seconds
Repeat Step I to IV
* Indicator ON, Indicator OFF
Human activity judgment is as following