71
17. Technical Data
17.1 Operation Characteristics
17.1.1 CS-E18NK CU-E18NK
Cooling Characteristic
o Room temperature: 81°F (DBT), 66°F (WBT)
o Operation condition: High fan speed
o Piping length: 24.6ft
o Compressor Frequency : Fc
57.000
58.000
59.000
60.000
61.000
62.000
63.000
60 65 70 75 80 85 90 95 100 105 110 115
Outdoor Air Temperature (°F)
Outlet Air
Temperature (°F
)
208 230
4.200
4.400
4.600
4.800
5.000
5.200
5.400
5.600
5.800
6.000
60 65 70 75 80 85 90 95 100 105 110 115
Outdoor Air Temperature (°F)
Cooling
Capacity (kW)
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
60 65 70 75 80 85 90 95 100 105 110 115
Outdoor Air Temperature (°F)
Current
(A)
133.000
135.000
137.000
139.000
141.000
143.000
145.000
147.000
60 65 70 75 80 85 90 95 100 105 110 115
Outdoor Air Temperature (°F)
Gas Side Piping
Pressure (PSI)