76
Piping Length Characteristic Cooling
o Room temperature: 81°F (DBT), 66°F (WBT)
o Operation condition: High fan speed
o Outdoor temperature: 95°F (DBT)
o Compressor Frequency : Fc
6.900
6.950
7.000
7.050
7.100
7.150
7.200
9 14192429 3439444954596469747984899499104
Piping Length (f t)
Cooling
Capacity (kW)
75.000
80.000
85.000
90.000
95.000
100.000
105.000
110.000
115.000
120.000
9 141924293439444954596469747984899499104
Piping Length (f t)
Gas Side Piping
Pressure (PSI)
53.600
53.800
54.000
54.200
54.400
54.600
54.800
55.000
55.200
55.400
9 141924293439444954596469747984899499104
Piping Length (f t)
Outlet Air
Temperature (°F
)
208 230
10.700
10.900
11.100
11.300
11.500
11.700
11.900
12.100
12.300
9 141924293439444954596469747984899499104
Piping Length (ft)
Current
(A)