Operation conditions
Use this air conditioner under the following temperature range.
DBT: Dry bulb temperature / WBT: Wet bulb temperature
Single split outdoor unit
CU-E7SKE, CU-E9SKE, CU-E12SKE,
CU-E15SKE, CU-E18SKE
Indoor Outdoor
DBT WBT DBT WBT
COOL
Max. 32 23 43 26
Min. 16 11 -10 -
HEAT
Max. 30 - 24 18
Min. 16 - -15 -16
°C (temperature)
Multi split outdoor unit
CU-3E18PBE, CU-4E23PBE,
CU-4E27PBE, CU-5E34PBE,
CU-2E12SBE, CU-2E15SBE,
CU-2E18SBE, CU-3E23SBE
Indoor Outdoor
DBT WBT DBT WBT
COOL
Max. 32 23 46 26
Min. 16 11 -10 -
HEAT
Max. 30 - 24 18
Min. 16 - -15 -16
°C (temperature)
To learn more...
The human activity sensor will also scan for area of heat source and movement in a room.
Detection area
• Based on area activeness horizontal air ow direction louver will adjust either x at
predetermined position or swing left/right periodically.
• The human activity sensor performance is in uenced by indoor unit location, movement
speed, temperature range, etc.
• The human activity sensor may:
- mistakenly detect an object with heat source & movement similar to human, such as
pets, etc.
- mistakenly detect as non-heat source & movement if a human stays motionless for
certain period of time.
• Do not place large objects near the sensor and keep away heating units or humidi er
from the sensor’s detection area. They may cause sensor malfunction.
7m
120º