lloydannaSep 6, 2025
Why is there a delay after restarting my Panasonic CU-TZ20TKE Air Conditioner?
- SsmithhaleySep 7, 2025
Operation is delayed a few minutes after restarting as a protection mechanism for the unit’s compressor.
Why is there a delay after restarting my Panasonic CU-TZ20TKE Air Conditioner?
Operation is delayed a few minutes after restarting as a protection mechanism for the unit’s compressor.
Why does airflow continue after my Panasonic CU-TZ20TKE Air Conditioner has stopped?
Airflow continues even after operation has stopped because of the extraction of remaining heat from the indoor unit, which can take up to 30 seconds.
Why does the indoor fan stop sometimes on my Panasonic CU-TZ20TKE?
The indoor fan stops occasionally during automatic fan speed setting to help remove surrounding odors.
Why does my room smell peculiar when using Panasonic CU-TZ20TKE Air Conditioner?
The room may have a peculiar odor because of a damp smell emitted by the wall, carpet, furniture, or clothing.
What causes the water flowing sound in Panasonic Air Conditioner during operation?
The water flowing sound during operation is due to the refrigerant flow inside the unit.
Why does mist emerge from my Panasonic CU-TZ20TKE indoor unit?
The mist emerging from the indoor unit is a condensation effect due to the cooling process.
Why is my Panasonic Air Conditioner making a cracking sound during operation?
The cracking sound during operation is caused by changes in temperature that lead to the expansion and contraction of the unit's components.
Why does the POWER indicator blink on my Panasonic Air Conditioner before it turns on?
The POWER indicator on your Panasonic Air Conditioner might blink before the unit is switched on as a preliminary step in preparation for operation when the ON timer has been set. When the ON Timer is set, the unit may start earlier (up to 35 minutes) before the actual set time in order to achieve the desired temperature on time.
Why is the cooling/heating capacity reduced on my Panasonic CU-TZ20TKE at the lowest fan speed?
If you've noticed a reduction in cooling/heating capacity during the lowest fan speed setting on your Panasonic Air Conditioner, it's because the low fan speed prioritizes low noise operation, which can reduce cooling/heating capacity. To increase capacity, increase the fan speed.
Why Panasonic CU-TZ20TKE unit doesn't receive signal from remote control?
If your Panasonic Air Conditioner unit isn't receiving the signal from the remote control, ensure that the receiver is not obstructed. Note that certain fluorescent lights may interfere with the signal transmitter; consult an authorized dealer for assistance.
Type | Split System |
---|---|
Cooling Capacity | 2.0 kW |
Heating Capacity | 2.5 kW |
Power Supply | 220-240 V, 50 Hz |
Refrigerant | R32 |
Indoor Unit Weight | 9 kg |
Air Flow (Indoor) | 9.4 m³/min |
Operating Temperature (Cooling) | -10 to 46°C |
Operating Temperature (Heating) | -15 to 24°C |
Explains how to select operation modes, start/stop the unit, and set the temperature.
Covers general warnings and cautions for unit operation, installation, and user safety.
Specific precautions for appliances filled with R32 refrigerant and handling safety.
Detailed precautions for R32/R410A, installation, operation, and avoiding damage.
Lists common symptoms that do not indicate malfunction and their potential causes.