1
Simultaneous (Twin) -Type
1-1. Unit Specifi cations
PEY1
6. 4-Way Cassette 60×60 Type S-50PY2E5A×2 / U-100PEY1E8
INDOOR MODEL S-50PY2E5A ×2
PANEL MODEL (CZ-KPY3A / CZ-KPY3B) ×2
OUTDOOR MODEL U-100PEY1E8
Branch pipe MODEL CZ-P155BK1
PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 / EN12102
POWER SUPPLY
ø, Hz 1ø 50Hz 3ø 50Hz
V 220 230 240 380 400 415 Min Max
C
O
O
L
I
N
G
CAPACITY
kW 10.0 10.0 10.0 2.7 11.0
BTU/h 34100 34100 34100 9200 37500
CURRENT A 0.35 × 2 5.85 5.55 5.40 - -
INPUT POWER
W 45 × 2 3.540k 3.540k 3.540k - -
TOTAL W - 3.630k 3.630k 3.630k 530 4.280k
ANNUAL CONSUMPTION
TOTAL kWh
*
4 - - - - 1815 - - -
EER/EER CLASS
TOTAL(W/W)
*
5/("A"~"G")
- - - 2.75 2.75/D 2.75 5.09 2.57
Erp
*
6
Pdsign kW - - - - 10.0 -
SEER (W/W) - - - - 6.0 -
Annual consumption
kWh - - - - 583 -
Class - - - - A+ -
POWER FACTOR % - - - 92 92 91
NOISE INDOOR
(H/M/L)
dB-A 40/37/33
Power Level dB 55/52/48
NOISE OUTDOOR
(H/L)
dB-A 54/-
Power Level dB 70/-
H
E
A
T
I
N
G
CAPACITY
kW 10.0 10.0 10.0 2.1 12.4
BTU/h 34100 34100 34100 7200 42300
CURRENT A 0.35 × 2 4.75 4.55 4.40 - -
INPUT POWER
W 40 × 2 2.885k 2.885k 2.885k - -
TOTAL W - 2.965k 2.965k 2.965k 410 4.280k
COP/COP CLASS
TOTAL(W/W)
*
5/("A"~"G")
- - - 3.37 3.37/C 3.37 5.12 2.90
Erp
*
6
Pdsign kW - - - - 9.2 -
Tbivalen °C - - - - -9 -
SCOP (W/W) - - - - 3.8 -
Annual consumption
kWh - - - - 3389 -
Class - - - - A -
POWER FACTOR % - - - 92 92 91
NOISE INDOOR
(H/M/L)
dB-A 40/37/33 -
Power Level dB 55/52/48 -
NOISE OUTDOOR
(H/L)
dB-A - 54/-
Power Level dB - 70/-
EXTRA LOW TEMP
Total CAPACITY(kW)/INPUT POWER(W)/COP
-
MAX CURRENT(A)/MAX INPUT POWER(W) 0.40/55 × 2 9.0/5.55k 9.0/5.80k 9.0/6.05k
STARTING CURRENT(A)/COMP OUTPUT(W) - - - 5.85/1.7k 5.55/1.7k 5.40/1.7k
NETWORK IMPEDANCE (ΩMAX.) - -
FM OUTPUT (W) 40 × 2 90
MOISTURE REMOVAL VOLUME L/h(Pt/h) 6.0 (3.0×2) (12.6) -
I/D AIR
FLOW
COOL m
3
/min (ft
3
/min)
11.1×2/9.8×2/8.5×2 (392)×2/(346)×2/(300)×2
HEAT m
3
/min (ft
3
/min)
11.1×2/9.8×2/8.7×2 (392)×2/(346)×2/(307)×2
O/D AIR
FLOW
COOL m
3
/min (ft
3
/min) 76 (2684)
HEAT m
3
/min (ft
3
/min) 67 (2366)
REFRIGERANT TYPE, AMOUNT
g
(oz) R410A 2.60k (91.7)
P
R
O
D
I
M
HEIGHT : H mm(inch) 260<265 + 23> (10-1/4) 996 (39-7/32)
WIDTH : W mm(inch) 575<583> (22-21/32) 940 (37-1/32)
DEPTH : D mm(inch) 575<583> (22-21/32) 340 (13-13/32)
Panel : H×W×D mm 3A:31 × 700 × 700, 3B:31 × 625 × 625
-
P
A
C
D
I
M
HEIGHT : H mm 345 (13-19/32) 1136
WIDTH : W mm 691 (27-7/32) 1055
DEPTH : D mm 691 (27-7/32) 485
MASS
(NET) k
g
(lb) 18 (40) 73 (161)
(GROSS) k
g
(lb) 23 (51) 81 (179)
Panel : (NET) k
g
(lb) 2.4 (5.3)
-
LAYERS LIMIT (actually) 11 (12) 2 (3)
Operation
Condition
Cool (DBT) 18°C ~ 32°C -10°C ~ 43°C
Heat (DBT) 16°C ~ 30°C -15°C ~ 24°C
P
I
P
I
N
G
PIPE DIAMETER mm (inch)
(Liquid)ø6.35(1/4) (Gas)ø12.7(1/2) (Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
CONNECT METHOD, STD LENGTH m (ft)
ared type, 5.0 (16.4) ared type, 5.0 (16.4)
PIPE LENGTH RANGE m (ft)
5 ~ 50 (16.4 ~ 164.0)
I/D&O/D HEIGHT DIFFERENCE m (ft)
15(OD located lower)/30(OD located higher) (49.2/98.4)
ADD GAS AMOUNT
g
/m (oz/ft)
50 (0.538)
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
30 (98.4)
*1: In case it is necessary to indicate the air flow volume in (l/s), the value in (m
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2: If the EUROVENT Certified models can be operated under the "extra-low" temperature condition, -7
°C
dry bulb and -8
°C
wet-bulb temperatures with rated voltage 230V
shall be used.
*3: Network Impedance shall be applicable for EUROPE and CHINA models.
*4: The annual consumption is calculated by multiplying the input power at 230V(400V) by an average of 500 hours per year in cooling mode.
*5: EER and COP classification is at 230V(400V) only in accordance with EU directive 2002/31/EC.
*6: SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season, Other fiche
data indicates in an attached sheet.
SM830231-02Single.indb205SM830231-02Single欧州.indb205 2014/09/1913:21:282014/09/1913:21:28

Other manuals for Panasonic CZ-KPY3A series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CZ-KPY3A series and is the answer not in the manual?

Panasonic CZ-KPY3A series Specifications

General IconGeneral
BrandPanasonic
ModelCZ-KPY3A series
CategoryAir Conditioner
LanguageEnglish

Related product manuals