EasyManua.ls Logo

Panasonic CS-CZ25ZKE - User Manual

Panasonic CS-CZ25ZKE
135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
© Panasonic Corporation 2023
Order No: PAPAMY2306065CE
Indoor Unit Outdoor Unit
CS-CZ25ZKE
CS-CZ35ZKE
CU-CZ25ZKE
CU-CZ35ZKE
Destination
Europe
WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service
or repair the products dealt with in this service information by anyone else could result in serious injury or death.
CAUTION
R32 REFRIGERANT – This Air Conditioner contains and operates with refrigerant R32.
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL.
Refer to Commonwealth, State, Territory and local legislation, regulations, codes, installation & operation manuals, before the
installation, maintenance and/or service of this product.
POWERFUL
FAN SPEED/
IMPORTANT SAFETY NOTICE
There are special components used in this equipment which are important for safety. These parts are marked by in the Schematic
Diagrams, Circuit Board Diagrams, Exploded Views and Replacement Parts List. It is essential that these critical parts should be replaced
with manufacturer’s specified
parts to prevent shock, fire or other hazards. Do not modify the original design without permission of
manufacturer.

Table of Contents

Questions and Answers:

Panasonic CS-CZ25ZKE Specifications

General IconGeneral
Cooling Capacity2.5 kW
Heating Capacity3.2 kW
Energy Efficiency Class (Cooling)A+++
Energy Efficiency Class (Heating)A++
RefrigerantR32
Power Supply220-240V, 50Hz
Outdoor Unit Dimensions (W x H x D)780 x 542 x 289 mm
Indoor Unit Weight9 kg
TypeSplit System
Noise Level (Indoor Unit)20 dB(A)
Noise Level (Indoor)19 dB(A)

Summary

Safety Precautions

Safety Precautions

Essential safety rules and warnings for installation and servicing.

R32 Refrigerant Precautions

Precaution for Using R32 Refrigerant

Specific safety measures and precautions for handling R32 refrigerant.

Unit Specifications

Specifications

Detailed technical specifications including cooling, heating, and electrical data.

Installation Instructions

Installation Instruction

Comprehensive guide for installing the air conditioning unit.

Select the Best Location

Guidelines for choosing optimal installation sites for indoor and outdoor units.

Indoor Unit

Procedures for indoor unit installation, including mounting plate and piping.

Indoor Unit Installation

Specific installation methods for the indoor unit based on piping configurations.

Outdoor Unit

Procedures for outdoor unit installation, including piping and leak testing.

Connect the Piping

Steps for connecting refrigerant piping, including flaring and torque specifications.

Air Tightness Test on the Refrigerating System

Method for performing air tightness tests on the refrigeration system using a vacuum pump.

Refrigerant System Service

Installation and Servicing Air Conditioner using R32

Procedures for installing and servicing units using R32 refrigerant.

Characteristics of R32 Refrigerant

Comparison of R32 characteristics with R410A and R22 refrigerants.

Refrigerant piping installation • Tools used in services

Details on refrigerant piping installation and the tools required.

Required Tools

A list of essential tools for refrigerant piping installation and servicing.

Repairing of refrigerant cycle; Brazing point

Techniques and procedures for brazing and repairing refrigerant cycles.

Operation Control

Basic Function

Overview of the basic functions and inverter control logic.

Quiet Operation (Cooling Mode;Cooling Area of Dry Mode)

How to activate and control quiet operation for cooling and dry modes.

Timer Control

Setting and operating ON and OFF timers for the unit.

+8;15°C Heat Operation

Special heating operation for low ambient temperatures to protect against cold.

Protection Control

Protection Control for All Operations

Safety controls that protect the unit during all operating modes.

Protection Control for Cooling & Soft Dry Operation

Specific protection controls active during cooling and soft dry modes.

Protection Control for Heating Operation

Protection controls specifically for heating operation.

Troubleshooting Guide

Refrigeration Cycle System

Diagnosing issues related to the refrigerant cycle, pressure, and temperature.

Breakdown Self Diagnosis Function

How to use the self-diagnosis function to identify errors.

Error Codes Table

A comprehensive table listing all error codes, their causes, and checks.

Self-diagnosis Method

Step-by-step troubleshooting methods for specific error codes.

H11 (Indoor;Outdoor Abnormal Communication)

Troubleshooting steps for communication errors between indoor and outdoor units.

Disassembly and Assembly Instructions

Indoor Electronic Controllers, Cross Flow Fan and Indoor Fan Motor Removal Procedures

Step-by-step instructions for disassembling indoor unit components.

To Remove Front Grille

Procedure for removing the front grille of the indoor unit.

To Remove Cross Flow Fan and Indoor Fan Motor

Steps to remove the cross flow fan and indoor fan motor.

Outdoor Electronic Controller Removal Procedure

Instructions for removing the electronic controller from the outdoor unit.

Technical Data

Cool Mode Performance Data

Performance data for cooling mode under various conditions.

Heat Mode Performance Data

Performance data for heating mode under various conditions.

Service Data

Piping Length Correction Factor

Correction factors for cooling and heating capacity based on piping length.

Exploded View and Replacement Parts List

Indoor Unit

Exploded view and part list for the indoor unit.