11
" 7HENANOBSTRUCTIONISPRESENTONTHEAIROUTLETSIDE
● When the upward area is open
(1) One outdoor unit installed individually (2) Two or more units installed side by side
*
a
a 500 mm or more
a
c
b
a 1,000 mm or more
b 250 mm or more
c 250 mm or more
* When also using the air-discharge chamber, provide a space of
500 mm or more.
● When an obstruction is present also in the upward area
(1) One outdoor unit installed individually (2) Two or more units installed side by side
a
c
b
a 500 mm or more
b 500 mm or less
c 300 mm or more
a
c
b
e
d
a 500 mm or more
b 250 mm or more
c 250 mm or more
d 500 mm or less
e 1,000 mm or more
(C) When an obstruction is present on both the air inlet and air outlet sides
#ASE7HENANOBSTRUCTIONONTHEAIROUTLETSIDEISHIGHERTHANTHEOUTDOORUNIT,(
(There is no height restriction on the air inlet side.)
● When the upward area is open
(1) One outdoor unit installed individually (2) Two or more units installed side by side
*
a
b
H
L
a 50 mm or more
b 500 mm or more
a
b
d
c
H
L
a 200 mm or more
b 1,000 mm or more
c 250 mm or more
d 250 mm or more
* When using the air-discharge chamber, provide a space of 300 mm
or more.
● WHENANOBSTRUCTIONISPRESENTALSOINTHEUPWARDAREA$ONOTUSETHEAIRDISCHARGECHAMBER
(1) One outdoor unit installed individually
a
A
c
L
H
b
a 200 mm or more
b 500 mm or less
c 1,000 mm or more
4HEDIMENSIONALRELATIONSHIPBETWEEN(!AND,ISAS
shown in the following table.
Unit: mm
, A
,
(
,
( 300
(,
( 500
(, )NSTALLTHEFRAMETOACHIEVE,
(
Close the area under the frame so that the outlet air does
not bypass there.
12
(2) Only two outdoor units installed side by side
b
a
A
c
L
H
a 200 mm or more
b 500 mm or less
c 1,000 mm or more
4HEDIMENSIONALRELATIONSHIPBETWEEN(!AND,ISAS
shown in the following table.
Unit: mm
, A
,
(
,
( 500
(,
( 750
(, )NSTALLTHEFRAMETOACHIEVE,
(
Close the area under the frame so that the outlet air does
not bypass there.
Only two outdoor units can be installed side by side.
#ASE7HENANOBSTRUCTIONONTHEAIROUTLETSIDEISLOWERTHANTHEOUTDOORUNIT,
(
(There is no height restriction on the air inlet side.)
● When the upward area is open
(1) One outdoor unit installed individually (2) Two or more units installed side by side
a
b
L
H
*
a 100 mm or more
b 500 mm or more
d
c
a
b
L
H
a 200 mm or more
b 500 mm or more
c 250 mm or more
d 250 mm or more
* When using the air-discharge chamber, provide a space of
300 mm or more.
● WHENANOBSTRUCTIONISPRESENTALSOINTHEUPWARDAREA$ONOTUSETHEAIRDISCHARGECHAMBER
(1) One outdoor unit installed individually
A
a
H
L
c
b
a 500 mm or more
b 500 mm or less
c 1,000 mm or more
4HEDIMENSIONALRELATIONSHIPBETWEEN(!AND,ISAS
shown in the following table.
Unit: mm
A
,
( 100
(, )NSTALLTHEFRAMETOACHIEVE,
(
Close the area under the frame so that the outlet air does
not bypass there.
(2) Only two outdoor units installed side by side
A
a
H
L
c
b
a 1,000 mm or more
b 500 mm or less
c 1,000 mm or more
4HEDIMENSIONALRELATIONSHIPBETWEEN(!AND,ISAS
shown in the following table.
Unit: mm
A
,
( 200
(, )NSTALLTHEFRAMETOACHIEVE,
(
Close the area under the frame so that the outlet air does
not bypass there.
Only two outdoor units can be installed side by side.
8