45
(EN)
Bluetooth® settingsBluetooth
®
settings
ECONAVI settings
(Menu Ú H&C settings Ú ECONAVI settings)
Circulation function on/off toggle
Set the direct/indirect airow*
2
.
Set the time that elapses before the Absence operation mode starts.
ECONAVI function on/off toggle
Set the Absence operation mode*
1
.
Direct/Indirect airow
• Direct airow: When the ECONAVI sensor detects a person, the unit
swings wind up and down around where the person is
present.
• Indirect airow: The unit avoids directly hitting wind at a person’s body.
Circulation
(When using Panel for
cassette (ECONAVI
type) only)
• Cooling: If the ECONAVI sensor detects high temperature of the oor
while group-controlling, the “Circulation” (air circulation)
is performed to alleviate the unevenness of temperature
between near the ceiling and near the oor.
• Heating: If the ECONAVI sensor detects low temperature of the oor,
the “Circulation” (air circulation) is performed to alleviate the
unevenness of temperature between near the ceiling and
near the oor.