26
8.2. When Replacing the Main P.C.B.
After replacing the Main P.C.B., be sure to achieve adjustment.
8.3. Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
Table S1 Extension Cable List
CAUTION (When servicing Flash P.C.B. Unit)
1. Be sure to discharge the E.Capacitor on Flash P.C.B. Unit.
Refer to "How to Discharge the E.Capacitor on Flash P.C.B. Unit.
The E.Capacitor voltage is not lowered soon even if the AC Cord is unplugged or the battery is removed.
2. Be careful of the high voltage circuit on Flash P.C.B. Unit.
3. DO NOT allow other parts to touch the high voltage circuit on Flash P.C.B. Unit
No. Parts No. Connection Form
1 VFK1870 PS9001(MAIN) PP8001(FLASH) 30pin B to B
2 VFK2024 FP9005(MAIN) LENS UNIT 51pin / 0.3 FFC
3 RFKZ0392 FP9007(MAIN) REAR OPERATION UNIT 14pin / 0.5 FFC
4 RFKZ0626 FP9002(MAIN) TOP CASE UNIT 21pin / 0.3 FFC
5 RFKZ0477 FP9003(MAIN) HINGE FPC UNIT-FP4101(LCD IF) 45pin / 0.3 FFC
6 VFK1716 FP9006(MAIN) MULTI FPC UNIT-TOP CASE UNIT 25pin / 0.3 FFC
7 RFKZ0631 FP9004(MAIN) JOINT FPC-FP9301(MIC JACK)/ SIDE OPERATION UNIT/ FRONT CASE UNIT 16pin / 0.4 FFC