EasyManuals Logo

Panasonic E series Operating Instructions

Panasonic E series
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
10
The unit stops and the TIMER indicator blinks.
Use remote control to retrieve error code.
Press until you hear beep sound, then
write down the error code
21
3
Press for 5 seconds
to quit checking
Turn the unit off and reveal the error code
to authorised dealer
4
Press for 5 seconds
For certain errors, you may restart the unit for limited operation with 4 beeps when operation starts.
Diagnostic
display
Abnormality/Protection
control
H 00
No memory of failure
H 11
Indoor/outdoor abnormal
communication
H 12
Indoor unit capacity unmatched
H 14
Indoor intake air temperature
sensor abnormality
H 15
Compressor temperature sensor
abnormality
H 16
Outdoor current transformer (CT)
abnormality
H 19
Indoor fan motor mechanism lock
H 21
Indoor oat switch operation
abnormal
H 23
Indoor heat exchanger
temperature sensor 1 abnormality
H 24
Indoor heat exchanger
temperature sensor 2 abnormality
H 27
Outdoor air temperature sensor
abnormality
H 28
Outdoor heat exchanger
temperature sensor 1 abnormality
H 30
Outdoor discharge pipe
temperature sensor abnormality
H 32
Outdoor heat exchanger
temperature sensor 2 abnormality
H 34
Outdoor heat sink temperature
sensor abnormality
H 35
Indoor drain water adverse
current abnormal
H 36
Outdoor gas pipe temperature
sensor abnormality
Diagnostic
display
Abnormality/Protection
control
H 37
Outdoor liquid pipe temperature
sensor abnormality
H 39
Abnormal indoor operating unit or
standby units
H 41
Abnormal wiring or piping
connection
H 97
Outdoor fan motor mechanism
lock
H 98
Indoor high pressure protection
H 99
Indoor operating unit freeze
protection
F 11
4-way valve switching
abnormality
F 17
Indoor standby units freezing
abnormality
F 90
Power factor correction (PFC)
circuit protection
F 91
Refrigeration cycle abnormality
F 93
Compressor abnormal revolution
F 95
Outdoor cooling high pressure
protection
F 96
Power transistor module
overheating protection
F 97
Compressor overheating
protection
F 98
Total running current protection
F 99
Outdoor direct current (DC) peak
detection
Troubleshooting

Other manuals for Panasonic E series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic E series and is the answer not in the manual?

Panasonic E series Specifications

General IconGeneral
BrandPanasonic
ModelE series
CategoryAir Conditioner
LanguageEnglish