<Ventilation Performance>
<Energy Performance>
FV-10VEC2
FV-10VEC2H
FV-10VEC2
FV-10VEC2H
Model No.
Model No. Mode
Heating
Cooling
Supply
temperature
Net air flow
Adjusted sensible
recovery efficiency
Sensible
recovery
efficiency
Total recovery efficiency
Net
moisture
transfer
Air
direction
Voltage
(V)
Frequency
(Hz)
Duct
Exhaust
Exhaust
&
Supply
Supply
Fan unit
Static
pressure
Net air flow
(CFM)
Power
consumption
(W)
Power
consumption
(W)
4“/6”
0.1”WG
0.4”WG
-25
4923
25
27
53
57-13
-25 30 64-13
32
°F °C L/s CFM
95 35
0
31 6632 0
40
60%
55%
29
77
100
32
663195 35 42
39
68
80%
65%
56%
77%
73%
83%
67%
60%
81%
77%
0.78
0.71
0.58
0.74
0.718532 0
FV-10VE2
FV-10VE2H
Model No. Mode
Heating
Cooling
Supply
temperature
Net air flow
Sensible
recovery
efficiency
Total recovery efficiency
Net
moisture
transfer
Power
consumption
(W)
4923
25 5332
°F °C L/s CFM
95 35
0
31 6632 0
40
60%
55%
29
32
663195 35 42
39
68
80%
77%
73%
83%
81%
77%
0.78
0.74
0.718532 0
120
100
100
100 81
90100
60
50
(22.4)
FV-10VE2
FV-10VE2H
Exhaust
&
Supply
4“/6”
0.1”WG
0.4”WG
120
100
100
100 81
90100
60
48
(21.6)
SPECIFICATIONS
Weight
Ib.()
For FV-10VEC2 and FV-10VEC2H
To ensure quiet operation of the ENERGY STAR certified H/ERV, each product model must be installed
using sound attenuation techniques appropriate for the installation.
The way your heat/energy-recovery ventilator is installed can make a significant difference to the
electrical energy you use. To minimize the electricity use of the heat/energy-recovery ventilator,
a stand-alone fully ducted installation is recommended. If you choose a simplified installation that
operates your furnace air handler for room-to-room ventilation, an electrically efficient furnace that has
an electronically commutated (EC) variable speed blower motor will minimize your electrical energy
consumption and operating cost.
Installation of a user-accessible control with your product model will improve comfort and may
significantly reduce the product model’s energy use.
This product earned the ENERGY STAR® by meeting strict energy efficiency guidelines
set by NaturalResources Canada and the US EPA. This product meets ENERGY STAR
requirements only when used in Canada.
The testing of the ventilation performance and the energy performance is in accordance with CSA-C439 standard.
Adjusted sensible
recovery efficiency