Cascading ampliers of the series connection type
* Cascading is not available for FX-505□-C2.
You can only cascade ampliers of the series connection type, i.e.
FX‑501□ and FX‑502.
Make sure that the power supply is OFF while adding or removing
ampliers of the series connection type.
If you cascade 2 or more ampliers, make sure to mount them on a
DIN rail. Refer to “3 Mounting” for details.
For each amplier using a main connection cable you can install a
maximum of 11 additional ampliers using sub cables.
If you connect 2 or more ampliers of the series connection type in
cascade, use the sub cable (optional) for the second series‑connec‑
tion-type amplier and all after.
Cascading ampliers
1. Mount the ampliers one by one on the
DIN rail.
2. Slide the ampliers next to each other
and connect the quick‑connection cables
(main cable for the rst amplier, sub
cables for all ampliers after the rst).
3. Mount the end plates MS-DIN-E (1,
optional) at both ends of the cascade so
that their at sides hold the ampliers
together.
4. Tighten the screws to x the end plates.
1
Removing cascaded ampliers
1. Loosen the screws of the end plates.
2. Remove the end plates.
3. Slide the last amplier away from the oth
ers and remove them one by one.
5
I/O circuit diagrams
FX-501 (NPN type)
+
12–24V DC
(+10% / -15%)
Main circuit
Brown, +V (see note)
Load
Black, sensing output
Blue, 0V (see note)
FX-501P (PNP type)
12 to 24V DC
(+10% / -15%)
+
Main circuit
Brown, +V (see note)
Load
Black, sensing output
Blue, 0V (see note)
* The quick-connection sub cable does not have +V (brown)
and 0V (blue). The power is supplied from the connector of the
main cable.
Terminal arrangement
1
2
3
Terminal no. Function
1
+V
2
Sensing output
3
0V
FX-502 (NPN type)
+
12–24V DC
(+10% / -15%)
Main circuit
Brown, +V (see note)
Load
White, sensing output 2 /
external input
Blue, 0V (see note)
Black, sensing output 1
* The quick-connection sub cable does not have +V (brown)
and 0V (blue). The power is supplied from the connector of the
main cable.
Terminal arrangement
1
2
3
4
Terminal
no.
Function FX-501
and FX-505
Function FX-502□
1
+V +V
2
Sensing output Sensing output 1
3
0V Sensing output 2 /
external input
4
── 0V
FX-502P (PNP type)
+
12–24V DC
(+10% / -15%)
Main circuit
Brown, +V (see note)
Load
Black, sensing output 1
Blue, 0V (see note)
White, sensing output 2 /
external input
FX-505-C2 (NPN type)
12–24V DC
(+10% / -15%)
(0–250Ω)
+
Main circuit
Brown, +V
Pink, external input
Load
Load
Load
White, sensing output 2
Blue, 0V
Gray, monitor current output (4–20mA)
Black, sensing output 1
FX-505P-C2 (PNP type)
12–24V DC
(+10% / -15%)
(0–250Ω)
+
Main circuit
Brown, +V
Pink, external input
Load
Load
Load
White, sensing output 2
Blue, 0V
Gray, monitor current output (4–20mA)
Black, sensing output 1
* Make sure to insulate the ends of all unused lead wires.