EasyManua.ls Logo

Panasonic FY-2509U1

Panasonic FY-2509U1
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Multiple products operate in group
●Please purchase necessary parts
following with local electrical
requirements, except the power
supply cord.
Power supply cord
Please select the switch of whose
capacity has 1.2
~
1.5 times total current,
when multiple products operate.
Earth leakage breaker protector
should be equipped, otherwise it may
cause an electrical shock.
The number of interlocking operation
is not more than 6.
WARNING
Wiring diagram
N
L
N
L
Motor
TERMINAL
Power
Source
Red
Orange
Black Black
Green/Yellow
Blue
Brown
Double Pole Switch
Customer Provide
(Contact Point Separate Distance Over 3mm)
Switch
White
White(H)
Yellow(L) Yellow
Operation of Control panel
/2:+,*+
FY-4009U1
OFF LOW HIGH
Operation methods
Representative model
1
Start to operate
2)) /2 +,
2
Select the mode of operation
/2 +,2))
/2 +,2))
Press “HI” or “LO” button to start the product as
shown in left figure.
Press “HI” button if high air velocity is required.
Press “LO” button if quiet and low velocity is
required.
Capacitor
8

Related product manuals